5.3.1 Hoist motor overheating supervision instructions

Param. Name

Description

4-4

T1

Temperature measurement channel 1 parameters

Selects the function of temperature measurement channel 1:

NU

Not used

Motor without thermistors or only one sensor that is connected to the
temperature input 2.

PTC

Motor thermistor or
Bimetal thermal switch

Two speed motors typically only have one set of thermistors, for both low speed
and high speed windings.

Bwear

Brake wear sensor

See section Hoist Brake- Wear supervision

A NTC

Type A NTC sensor

B NTC

Type B NTC sensor

4-4-1

T1 operat.

C NTC

Type C NTC sensor

Determines the type of thermistors in the low speed windings, connected to the
temperature input 1
Manufacturer’s hoisting motors used in motor-torque calculation overload
systems are as a standard equipped with type B NTC thermistors

Param. Name

Description

4-5

T2

Temperature measurement channel 2 parameters

Selects the function of temperature measurement channel 2:

NU

Not used

Motor without thermistors or only one sensor that is connected to the
temperature input 1.

PTC

Motor thermistor or
Bimetal thermal switch

Two speed motors typically only have one set of thermistors, for both low speed
and high speed windings.

Bwear

Brake wear sensor

See section Hoist Brake- Wear supervision

A NTC

Type A NTC sensor

B NTC

Type B NTC sensor

4-5-1

T2 operat.

C NTC

Type C NTC sensor

Determines the type of thermistors in the low speed windings, connected to the
temperature input 1
Manufacturer’s hoisting motors used in motor-torque calculation overload
systems are as a standard equipped with type B NTC thermistors

Param.

Value

Description

Note

4-10
Single sup

Accessible with password 4: 8124

4-10-1
OT run ?

No / Down

Hoisting and lowering is prevented when the
overtemperature supervision trips.

If, for safety reasons, local legislation or customer demands,
lowering the load is required when the temperature supervision
has tripped, set this parameter to: “Down”

4-10-2
OT limit

150C

Sets the tripping level of the overtemperature
supervision in degrees Celsius, steps of one
degree. Only with NTC-thermistor.

Consult with the motor data sheets for the maximum allowed
temperature for the motor. Default for manufacturer’s squirrel
cage motors: 150°C