Output Voltage and Current Ratings

MODEL

OUTPUT VOLTAGE

MAX OUTPUT

VOLTAGE

RIPPLE &

LINE

LOAD

POWER

EFF.

Preset

Range

CURRENT

TOLERANCE

NOISE

REG.

REG.

Max.

PDN10-12

12V

10.8 - 13.2V

0.84A

±1%

100mV

±1.0%

±1.0%

10.08W

81%

PDN10-15

15V

13.5 - 16.5V

0.67A

±1%

100mV

±1.0%

±1.0%

10.05W

81%

PDN10-24

24V

21.6 - 26.4V

0.42A

±1%

120mV

±1.0%

±1.0%

10.08W

81%

PDN20-12

12V

10.8 - 13.2V

1.7A

±1%

100mV

±1.0%

±1.0%

20.4W

83%

PDN20-15

15V

13.5 - 16.5V

1.4A

±1%

100mV

±1.0%

±1.0%

21W

85%

PDN20-24

24V

21.6 - 26.4V

1A

±1%

120mV

±1.0%

±1.0%

24W

86%

PDN40-12

12V

10.8 - 13.2V

3.4A

±1%

100mV

±1.0%

±1.0%

40.8W

84%

PDN40-15

15V

13.5 - 16.5V

2.7A

±1%

100mV

±1.0%

±1.0%

40.5W

84%

PDN40-24

24V

21.6 - 26.4V

1.7A

±1%

120mV

±1.0%

±1.0%

40.8W

84%

PDN40-48

48V

43.2 - 52.8V

0.85A

±1%

180mV

±1.0%

±1.0%

40.8W

85%

PDN60-12

12V

10.8 - 13.2V

5A

±1%

100mV

±1.0%

±1.0%

60W

86%

PDN60-15

15V

13.5 - 16.5V

4A

±1%

100mV

±1.0%

±1.0%

60W

87%

PDN60-24

24V

21.6 - 26.4V

2.5A

±1%

120mV

±1.0%

±1.0%

60W

87%

PDN60-48

48V

43.2 - 52.8V

1.25A

±1%

180mV

±1.0%

±1.0%

60W

88%

PDN100-12

12V

10.8 - 13.2V

7.5A

±1%

180mV

±1.0%

±2.0%

90W

87%

PDN100-15

15V

13.5 - 16.5V

6.4A

±1%

180mV

±1.0%

±2.0%

96W

87%

PDN100-24

24V

21.6 - 26.4V

4A

±1%

180mV

±1.0%

±2.0%

96W

88%

PDN100-48

48V

43.2 - 52.8V

2A

±1%

250mV

±1.0%

±2.0%

96W

87%

Notes.
1. All parameters NOT specifically mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1µF ceramic & 47µF electrolytic parallel capacitors.
3. Tolerance includes set up tolerance, line regulation and load regulation.
4. De-rating mat be needed under low input voltages. Check the de-rating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
6. In parallel connection, only one unit may operate if the output load is less than 5% of rated output load.

Mechanical & Connection Details

W

W

D

H

H

PDN10, PDN20

PDN40, PDN60, PDN100

Dimensions

Model

Width (W) Height (H) Depth (D)

PDN10 & PDN20

23

90

99

PDN40 & PDN60

40

90

99

PDN100

55

90

99

All dimensions in mm