High density dc-dc modules, Output voltage and current ratings, External output trim remote on/off control – Powersolve PS200 Series User Manual

Page 2: Mechanical and connection details, Output noise, Pin connection

Advertising
background image

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]

www.powersolve.co.uk

High Density DC-DC Modules

Output Voltage and Current Ratings

All specifications typical at nominal line, full load and 25°C unless otherwise stated.

All dimensions in inches (mm)
Tolerances

Inches

x.xx ±0.02

x.xxx ±0.010

Pin ±0.02

Millimeters x.x ±0.5

x.xx ±0.25

Pin ±0.5

External Output Trim

Remote ON/OFF Control

MODEL

INPUT

OUTPUT

OUTPUT

INPUT CURRENT

% EFF.

VOLTAGE

VOLTAGE

CURRENT

NO LOAD

FULL LOAD

PS200-48S25

36-75 VDC

2.5 VDC

40A

25mA

2.8A

74

PS200-48S33

36-75 VDC

3.3 VDC

40A

25mA

3.5A

79

PS200-48S05

36-75 VDC

5 VDC

40A

25mA

5A

83

PS200-48S12

36-75 VDC

12 VDC

17A

25mA

5A

85

PS200-48S15

36-75 VDC

15 VDC

13.3A

25mA

5A

85

PS200-48S24

36-75 VDC

24 VDC

8.33A

25mA

5A

85

PS200-48S28

36-75 VDC

28 VDC

7.14A

25mA

5A

85

PS200-48S48

36-75 VDC

48 VDC

4.2A

25mA

5A

85

NOTE: Nominal Input Voltage 48VDC

Mechanical and Connection Details

The PS200 Series allows the user to switch the module on and off electronically with the remote on/off feature.
The PS200 Series are available with “positive logic” or “negative logic” (option).

Logic State

(Pin 2)

Negative

Logic

Positive

Logic

Logic low-

Switch closed

Module on

Module off

Logic high-

Switch open

Module off

Module on

Output Noise

The output can be trimmed externally (±10%) using a fixed resistor or
a trimpot as shown.

The output noise is measured with a 10µF tantalum and a 1.0µF
ceramic capacitor across the output.

Logic Table

Pin Connection

Pin

Function

1

+Vin

2

ON/OFF

3

CASE

4

-Vin

5

-Vout

6

-Sense

7

Trim

8

+Sense

9

+Vout

Advertising