High density dc-dc modules – Powersolve PS200 Series User Manual

Page 3

Advertising
background image

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]

www.powersolve.co.uk

High Density DC-DC Modules

Application Note

Derating:
The case operating temperature range of the PS200 series is -40°C to +100°C. When operating the PS200 series, proper derating or
cooling is required.

Following is the derating curve for the PS200 without a heatsink; airflow along width (transverse).

Where:

The power dissipated (Pd):
Pd = Pi - Po = Po (1-n) / n

The thermal resistances are listed below:

Chart of Thermal Resistance vs Air Flow:

AIR FLOW RATE

TYPICAL Rca

Natural Convection 20ft/min. (0.1m/s)

3.82°C/W

100ft./min. (0.5m/s)

3.23°C/W

200ft./min. (1.0m/s)

2.71°C/W

300ft./min. (1.5m/s)

2.28°C/W

400ft./min. (2.0m/s)

1.92°C/W

500ft./min. (2.5m/s)

1.68°C/W

600ft./min. (3.0m/s)

1.50°C/W

700ft./min. (3.5m/s)

1.35°C/W

800ft./min. (4.0m/s)

1.23°C/W

The temperature rise (∆T):

∆T = Pd * Rca

Advertising