4 install the wiring, 5 adjust the levels & scale factors – Crown Audio IQ-P.I.P.-SMT User Manual

Page 22

Advertising
background image

Page 22

IQ P.I.P.–SMT

P.I.P.

MODULE

BACK PANEL

OF PIP2

AMPLIFIER

PIP2 CONNECTOR

BOARD

Fig. 4.7 Installation into a PIP2

Amplifier

cables should extend below
the

PIP2 input adapter.

Next, insert the edge con-
nector of the

IQ–P.I.P.–SMT

into the

PIP2 input adapter

(see Figure 4.7) and insert
the assembly into the

P.I.P.

opening in the back of the
amplifier.

4.4 Install the Wiring

11.

Connect the

IQ–P.I.P.–SMT

to the

IQ System via the

Crown Bus.

See Section 4.6

for full instructions.

12.

Connect the audio signal

wiring

to the

IQ–P.I.P.–SMT.

This includes the XLR input

wiring and, if desired, the
phone jack daisy chain wir-
ing. See Section 4.7 for full in-
structions.

13.

Reconnect amplifier to the
AC receptacle.

4.5 Adjust the Levels & Scale

Factors

14.

Turn the level controls of
the amplifier to their full or
maximum setting.

This is re-

quired by the

IQ–P.I.P.–SMT.

If needed, use the software-
controlled input attenuators
on the

IQ–P.I.P.–SMT to re-

duce the audio levels.

15.

Configure the amplifier
scale factors.

(Standard

P.I.P.-compatible amplifiers
only—the scale factors for
PIP2-compatible amplifiers
are set automatically.) It is
necessary to configure soft-
ware scale factors in the mi-
croprocessor of the
IQ–P.I.P.–SMT in order for it to
properly interpret the output
signal level of the amplifier
model in which it is installed.
This is easily done by con-
necting a host computer to
the

IQ–P.I.P.–SMT via an IQ

interface and the Crown Bus
and running the appropriate
software (see the IQ software
User’s Manual for details).
The software will prompt you
for the amplifier model and
send the appropriate scale
factors to the

P.I.P. The scale

factor values are listed in Fig-
ure 4.8 along with the set-
tings of jumpers JP4 and JP5.

Note: Since it is possible to
configure one channel of a

A

B

B

A

18 PIN (B)

20 PIN (A)

Q43528-1

FROM AMPLIFIER

Fig. 4.6 PIP2 Input Adapter

Connection

10.

Tighten the two

P.I.P.

mounting screws

until the

P.I.P. is secured to the ampli-
fier back panel.

Advertising