3.9. Remote Configuration


Parani-SD1000 supports remote configuration. After connecting to the Parani-SD1000 through
Bluetooth, before sending any other character, send three escape character (default :+). Then, the
Parani-

SD1000 will enter remote configuration mode and print “Please Enter Password”. You have to

enter the password with “AT+PASS” command within 2 minutes. After the password authentication,
you are able to enter any at command except “ATH”, “ATO”, “ATD”, “AT+BTSCAN”, “AT+BTINQ?” and
“AT+BTCANCEL”. The default password is “0000” and it is configurable with “AT+CHPASS” command.


Example of remote configuration mode.











3.10. Software and Utility


This configuration software and utility for firmware update is included with the product, which also can
be downloaded from http://www.sena.com

Table 3-9 Configuration Software

Software

Purpose

Operating System

ParaniWIN

Configuration

MS Windows 98SE or Higher

ParaniMultiWizard

Multi Configuration

MS Windows 98SE or Higher

ParaniUpdater

Firmware Update

MS Windows 98SE or Higher

3.11. ParaniWIN


ParaniWIN is a program that runs on Microsoft Windows for the configuration of Parani-SD1000.
Install ParaniWIN on your computer. Plug a Parani-SD1000 into the serial port of the computer and
turn on the power. Run ParaniWIN.

Figure 3-2 Serial Port Setting

CONNECT 000195000001
+++
Please Enter Password
AT+PASS=0000
Remote Configuration Enabled
AT+BTINFO?
000195000001,SD1000v2.0.3-095515,MODE0,CONNECT,0,0,HWFC