options works well in case that only one of the devices between Master and Slave use the Encryption
option.




Parani-

SD1000 has 4 response messages, „OK‟, „ERROR‟, „CONNECT‟, and „DISCONNECT‟. In

some cases, these responses can affect the host system unexpectedly. To prevent this, user can set
the Command response to ON or OFF.

For Parani-SD1000, hardware flow control can be configured only by dip switch. And parity, stop bit
can be configured only SW config mode. Thus H/W Flow Control option will not work in this case.
When the dipswitch value isn‟t ATcommand mode, the Baud Rate menu will be disabled.

Click [Apply] button to apply any changes made to the Parani-SD1000.

Connection(out) icon will show the following window to search and connect other Bluetooth devices.



Figure 3-7 Connection (out) Window




Click [Search] button to search nearby Bluetooth devices. Once several Bluetooth devices has been
found, select one of the devices and click the [Connect] button. The selected Bluetooth device must be
discoverable and connectable. Click [Disconnect] button to cancel the connection.



After the connection has been established, you will be able to test signal strength by pushing the
START button.