Aqua-Pure ASB1001 User Manual

Page 14

Advertising
background image

h.

Plug control valve in the original electrical outlet. Open water inlet valve. The valve should continue where it left off. Backwash the unit as describe
in step 12 on page 2-4.

i.

Once the waste water is clear, open the outlet side of bypass valve and check the water color and pressure at a sink or lavatory to ensure the fi lter is
completely ready to use.

j.

Check clock to ensure the correct time of day is set. If not refer to section 2 of this manual to set correctly.

Note: It is normal to see milky colored water when the valve is in the backwash position (the display will read C1). However, at the end of the second
fast rinse (the display will read C4) the line should be clear. If the fast rinse water continues to appear milky, contact

Technical Support Services @

1-800-222-7880 for resolution.

3-2

Advertising