Aqua-Pure ASB1001 User Manual

Page 16

Advertising
background image

12. Time of day fl ashes on and off.

A. Power has been off for more than eight hours.

1. Reset the time of day.

B. Transformer was unplugged from either wall

outlet or from PC board.

1. Reset the time of day.

C. SET HOUR was pressed.

1. Reset the time of day.

13. Valve stalled in backwashing.

A. Motor not operating.

1. Replace motor.

B. No power at the outlet

1. Repair outlet or use a working one.
2. Check circuit breaker at the main power box.

C. Damaged transformer.

1. Replace transformer.

D. Damaged PC board.

1. Replace PC board.

E. Damaged drive gear or drive cap assembly.

1. Replace gear or drive cap assembly.

F. Damaged piston retainer.

1. Replace main piston assembly.

G. Damaged main piston.

1. Replace main piston assembly.

14. Valve does not regenerate automatically

when the

and

buttons are pushed.

A. Transformer unplugged.

1. Connect transformer and the PC board power

B. No power at outlet.

1. Restore or repair power source.

C. Damaged drive gear or drive cap assembly.

1. Replace gear or drive cap assembly.

D. Damaged PC board.

1. Replace PC board.

15. Valve does not regenerate automatically,

but does when

and

are depressed.

A. Programming error.

1. Review programming of control valve.

B. Damaged PC board.

1. Replace PC board.