SYSTEM AND PLUMBING SET-UP INSTRUCTIONS

CAUTION

CAUTION

To reduce the risk associated with property damage due to water leakage:

Installation must comply with existing state or local plumbing codes, even if they are contrary to our instructions.
Do not use a torch or other high temperature sources near fi lter system, cartridges, plastic fi ttings or plastic plumbing.
• On plastic fi ttings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic.
• Take care when using pliers or pipe wrenches to tighten plastic fi ttings, as damage may occur if over tightening occurs.

IMPORTANT NOTES

IMPORTANT NOTES

Damage due to heat is not covered under the manufacturer’s warranty and will void the warranty.

The use of fl exible drain lines are prohibited in some states, check with your local code offi cer for requirements. Distance and height affects the
performance of the drain line to discharge at the proper rate to effectively backwash the fi lter media. The following are guidelines for drain line size
installation. Do not bend the drain line too sharply if using fl exible tubing. Secure the drain line over the discharge line to prevent splashing or blow
out during regeneration. Do not use garden hose or vinyl tubing as a drain line as this may cause a failure to regenerate properly.

Step 1

Inspect and open factory sealed box to ensure all components required for installation are present. If media was ordered, verify the amount and type of
fi lter media (ordered separately) is correct. (See Section 6, page 6-2.)

Step 2

Remove fi ltration system from shipping carton and inspect to ensure there is no damage to product from shipping. Inspect any packing for components that
have been attached for shipping before discarding. If any items intended for installation are missing at this time contact your Dealer/Installer or our Customer
Service Department at 1-800-222-7880 to notify them of this situation. Provide the model number and serial number when contacting Customer Service.

Step 3

Threaded Tank Models: APPM100, APPM150, APPM200, APPM100M, APPM150M, APPM200M: Follow the steps to center the distributor tube and load the
fi lter media into the media tank for successful installation of the APPM Iron Reduction Filtration System.

a.

Remove the control valve from the media tank by rotating the valve head assembly to the left (counter-clockwise) and set aside to reassemble after
media is loaded into tank.

b.

Tilt media tank to a 45 degree angle until gravel shifts to the side of the tank and dimple at bottom of media tank is visible. This will allow you to
place the distributor tube basket assembly in the dimple on the bottom of the media tank.

c.

Place media tank back in upright position and ensure gravel at the bottom of the media tank is level. Place red plastic cap on the distributor tube
that is provided in the parts bag.

d.

Locate the fi lter media that will be used in the iron reduction fi lter and load into the media tank. Note: fi ll only to the labeled line on the outside of
the media tank. Refer to Section 6 Specifi cation and Operating Data, page 6-1, for the correct quantity for your fi lter system. Use a clean rag to wipe
the opening of the media tank to remove any dust or sediment before moving to the next step.

Dome Hole Tank Models: APPM100DM, APPM100MDM, APPM150DM, APPM150MDM, APPM200DM, APPM200MDM:

a.

Add media through fi llport cap located on tank using funnel (See FILLING MEDIA TANK below). Fillport cap can be removed by turning a quarter turn
counter clockwise.

CAUTION

CAUTION

To reduce the risk associated with skin, eye, and respiratory tract irritation from dust

from fi lter media during installation:

• Gravel and several types of fi lter media may be used in this product, depending upon the

application. During installation, dust may cause irritation to skin, eyes, and respiratory tract,
and may affect lungs.

• Utilize a NIOSH-approved dust fi lter mask and appropriate eye protection when handling and

pouring gravel and fi lter media.

• To request an MSDS relating to this product, call 203-238-8965 or go to www.3M.com ,

select country, and use the search engine to search MSDS. For emergencies, call 800-364-
3577 or 651-737-6501 (24 hours).

b.

Reinstall fi llport cap by turning a quarter turn clockwise.

c.

If bypass valve assembly is not factory pre-installed, attach using clips and screws.

d.

Using a clean dry rag, wipe the opening of the media tank to remove any dust or residue from the opening to receive the control valve. Attach the
valve head to the media tank by rotating the valve head assembly to the right (clockwise).

3-4

FILLING MEDIA TANK

Advertising