OSRAM HALOTRONIC-COMPACT – HTM, HTN User Manual

Halotronic, A 2. 1. b 3. correct incorrect, Wire stripping (see table)

Advertising
background image

Electronic transformers for 12 V
halogen lamps
• Optimum lamp life
• Compact for small spaces
• Reversible switch off in case of short-

circuits, overload and overtemperature

• Dimming on the primary side is

possible. A corresponding dimmer
has to be used (suitable dimmers see
table)

Connecting the transformers to the
lamps
• Ensure that the lamp load is within the

output range of the transformers (see
table)

• Transformers can be connected in

parallel on the primary side (fig. 1a)

• Do not connect the transformers in

parallel or series on the secondary
side (fig. 1b)

• The maximum load of the transformer

can be connected to any of the lamp-
side terminal pairs (except HTL 225)

Wiring
• In accordance with the EN 60598

standard, the recommended
connecting cables (see table) must be
held firmly by the cable clamp to
prevent it from being pushed or pulled

• Secondary side: cable length maximum

2 m, minimum 0.3 m (fig. 2 and 3)

• To prevent radio interference keep lamp

cables as short as possible, keep them
away from metal surfaces and keep
them separated as far as possible from
mains cables (fig. 2 and 3: angles ≥ 90°).

Do not route cables along the
transformers

• When using single leads of a cable,

secondary wires have to be twisted
in pairs

• For units installed in fixtures the

luminaire manufacturer is responsible
for RFI-compliance

Temperatures
• Avoid high temperatures. Do not place

the transformers close to the lamp
(minimum distance 0.3 m). Maximum
permissible ambient temperature must
not be exceeded (see table). Make sure
there is adequate space to avoid a
build-up of heat. In critical installations
the temperature at t

c

has to be

controlled

Caution
• Transformers must be installed by a

qualified electrician

• Electronic transformers are not suitable

for any other load than low voltage
halogen lamps

• No switching or dimming on secondary

side

HALOTRONIC

®

1. a

2.

1. b

3.

correct

incorrect

35 W
35 W

35 W

100 W

HALOTRONIC

105 W

HALOTRONIC

105 W

HALOTRONIC

105 W

35 W

4. Wire stripping (see table)

Prim.

Sec.

Optimum
area for
primary cable

Optimum
area for
secondary
cables

230 – 240 V
50 – 60 Hz

max. 2 m

min. 0.3 m

HTM 70

HTM 1

0

5

HTN 75

90°

90°

Optimum
area for
primary cables

Optimum
area for
secondary
cables

Prim.

Sec.

HTL 105
HTL 225
HTM 150

max. 2 m

min. 0.3 m

90°

mains

next
unit

not used

A

B

10 W

120 W

HALOTRONIC

105 W

HALOTRONIC

105 W

HALOTRONIC

105 W

HALOTRONIC

105 W

Advertising