Halotronic – OSRAM HALOTRONIC-COMPACT – HTM, HTN User Manual

Page 2

Advertising
background image

NYM(3 x1.5) mm

2

H05VV-F(2 x 0.75) mm

2

H03VV-F(2 x 0.75) mm

2

H03VVH2-F(2 x 0.75) mm

2

HTN 75/230-240 I HT

120/230-240/12

LF

HTL

105/230-240

HTL

225/230-240

230 V – 240 V

207 V – 254 V

207 V – 264 V

207 V – 264 VAC, 176 V – 275 VDC

176 V – 275 V

0.32 Aeff 0.48

Aeff 0.44

Aeff

0.90

Aeff

50 – 60 Hz

50 Hz

0; 50 – 60 Hz

11.5 V (75 W),

11.5 V (120 W),

11.6 V (105 W),

11.6 V (225 W),

11.7 V (20 W)

11.5 V (35 W)

11.3V (35 W)

11.7 V (50 W)

max. 4 W (75 W)

max. 6 W (120 W)

max. 6 W (105 W)

max. 9 W (225 W)

20 W – 75 W

35 W – 120 W

35 W – 105 W

50 W – 225 W

EN 55015; EN 61000-3-2; EN 61547; EN 61047; IEC 61347

0 °C to +50 °C

-20 °C to +45 °C

-20 °C to +50 °C

0.37 Aeff (75 W)

2 Aeff (120 W)

0.6 Aeff (105 W)

1.5 Aeff (225 W)

trailing edge phase control

trailing or leading edge phase control

automat. switch off, reversible

automat. switch off, reversible

automat. switch off, reversible

H03VV-F2 x 0.50 mm

2

; H03VV-F2 x 0.75 mm

2

; H05VVH2-F2 x 0.75 mm

2

;

H03VVH2-F2 x 0.75 mm

2

; NYM-O 2 x1.5 mm

2

; NYM-J 3 x1.5 mm

2

; H05VV-F2 x 2.5 mm

2

H03VV-F2 x 0.75 mm

2

; H05VVH2-F2 x 0.75 mm

2

; NYM-O 2 x1.5 mm

2

;

H05VV-F2 x1.5 mm

2

; H05VV-F2 x 2.5 mm

2

; NYM-J 3 x1.5 mm

2

; NYM-J 3 x 2.5 mm

2

10 mm

15 mm

14 mm

6 mm

7 mm

8 mm

HTM 70/230-240

HTM 105/230-240

HTM 150/230-240

Nominal line voltage:

230 V – 240 V

Operating voltage:

207 V – 254 V

Safe operation:

207 V – 264 V

Nominal line current:

0.27 Aeff 0.41

Aeff 0.57

Aeff

Line frequency:

50 – 60 Hz

Output voltage (230 V):

11.2 V (70 W); 11.2 V (20 W)

11.3 V (105 W); 11.4 V (35 W)

11.4 V (150 W); 11.5 V (50 W)

Losses:

max. 4 W (70 W)

max. 6 W (105 W)

max. 7 W (150 W)

Load range:

20 W – 70 W

35 W – 105 W

50 W – 150 W

Standards:

EN 55015; EN 61000-3-2; EN 61547; EN 61047; IEC 61347

Approvals:

Temperature range:

0 °C to +50 °C 0

°C to +45 °C

Max. inrush current for cold lamps:

0.3 Aeff (70 W)

1.0 Aeff (105 W)

1.1 Aeff (150 W)

Dimming: trailing

or leading edge phase control for inductive load dimmers

Short circuit protection:

automat. switch off, reversible

Overload protection:

automat. switch off, reversible

Overheating protection:

automat. switch off, reversible

Suitable cable types for primary side:

HALOTRONIC

®

Nominal line voltage:

Operating voltage:

Safe operation:

Range of battery voltage for
emergency installation:

Nominal line current:

Line frequency:

Output voltage (230 V):

Losses:

Load range:

Standards:

Approvals:

Temperature range:

Max. inrush current for cold lamps:

Dimming:

Short circuit protection:

Overload protection:

Overheating protection:

Suitable cable types for primary side:

Suitable cable types for secondary side:

Stripping lengths (fig. 4):

A

B

connection of 3 lines of the types NYM 3 x1.5;

H05VV-F(2 x1.5 – 2 x 0.75); H03VV-F(2 x1.5 – 2 x 0.75)

Halogen low voltage line 2 x1.5; 2 x 2.5:

cable sheath cross section (6 x 3.5) mm

2

to (9 x 6) mm

2

connection of 2 lines of the types

NYM 3 x1.5; H05VV-F(3 x1.5 – 3 x1.0)

NYM(3 x1.5) mm

2

; H05VV-F(3 x 0.75 – 3 x1.5) mm

2

H05VV-F(2 x 0.75 – 2 x1.5) mm

2

; H05VV-H2F(2 x 0.75 – 2 x1.5) mm

2

Stripping lengths (fig. 4):

A

12 mm

12 mm

B

7 mm

8 mm

NYM(3 x1.5) mm

2

H05VV-F(3 x 0.75 – 3 x1.5) mm

2

H05VV-F(2 x 0.75 – 2 x1.5) mm

2

H05VVH2-F(2 x 0.75 – 2 x1.5) mm

2

cable sheath cross section (6 x 3.5) mm

2

to (8 x 5) mm

2

same cable type recommended as used at primary side

the sheath cross section must be equal to that of primary side

Suitable cable types for secondary side:

connection of 6 lines of the types H05VV-F2 x 0.75;

H03VV-F2 x 0.75 Halogen low voltage line 2 x1.5:

cable sheath cross section (6 x 3.5) mm

2

to (7 x 5) mm

2

OSRAM GmbH
Steinerne Furt 62
86167 Augsburg, Germany

www.osram.com

G10252879

C10238698