10

Specification

Electrical Characteristics

Supply Voltage

DC +3.7V ±5%

Battery Type

Li-ion battery (1100mAh)

Recharge Time

5 Hours

Operating

30,000 times scan at
continuous mode

Current Draw
Power On (Typ.)

180mA

Stand by (Typ.)

0.1mA

a) Scanner

Operation (Typ.)

180mA

Supply Voltage

DC +5V ±5%

Current Draw
Power On (Typ.)

60mA

Stand by (Typ.)

60mA

b) Receiver

Operation (Typ.)

60mA

Performance

Light Source

639 nm Red LED

Sensor

Linear CCD Sensor

Processor Type

8051 compatible

Operating Freq.

36.864 MHz

Scan Rate

270 scans/sec

Reading Distance

270 mm

Width of Field

80 mm

Print Contrast Ratio

PCS [email protected]

Resolution

0.1mm @ PCS 0.9

Ambient Light

100000 Lux Max. @
Direct sun light

Reading Angle

Test Conditions:Code
39, 10mil, PCS 0.9

Forward & Backward

± 70 Degree

Left & Right

± 60 Degree

a) Scanner

Characteristics

Dead Zone

± 5 Degree

Frequency Baud

426MHZ~442MHZ
/1MHZ step

Frequency Stability

±30KHZ @ -20

o

C

~+85

o

C

Modulation Method

FSK (Frequency Shift
Keying)

Working BandWidth

Below 250KHz

Data Rate

19.2Kbps

Stray Power

-50dBm

Emission Power

3.5±1dBm

Receiving Sensitivity

≦-90dBm

b) Radio

Characteristics

Radio Range

15m for Open Air

Environmental
Operating Temperature

-10

o

C to 40

o

C (32

o

F to 102

o

F)

Storage Temperature

-20

o

C to 70

o

C (-4

o

F to 158

o

F)

Relative Humidity

20% to 95% (Non-condensing)