Car2512fp series rectifier, Data sheet, Input: 90v – GE Industrial Solutions CAR2512FP Front-End User Manual

Page 3: Output: 12 v, Or 5 v, Main output (continued), General specifications, Feature specifications

Advertising
background image

GE

Data Sheet

CAR2512FP series rectifier

Input: 90V

AC

to 264V

AC

; Output: 12 V

DC

@ 2500W; 3.3V

DC

or 5 V

DC

@ 1A

April 23, 2013

©2013 General Electric Company. All rights reserved.

Page 3

12V

DC

MAIN OUTPUT (continued)

Parameter

Symbol

Min

Typ

Max

Unit

Remote ON/OFF delay time

40

ms

Turn-ON rise time (10 – 90% of V

OUT

)

50

ms

Transient response 50% step [10%-60%, 50% - 100%]
(dI/dt – 1A/µs, recovery 300µs)

V

OUT

-5 +5

%V

OUT

Programmable range (hardware & software)

10.8

13.2

V

DC

Overvoltage protection, latched

(recovery by cycling OFF/ON via hardware or software)

13.8 14.8 15.8 V

DC

Output current [V V

IN

= HL

V

IN

= LL

I

OUT

0

208
100

A

DC

Current limit, Hiccup (programmable level)

110

130

% of FL

Active current share

-5

+5

% of FL

STANDBY OUTPUT

Parameter

Symbol

Min

Typ

Max

Unit

Set point

V

OUT

3.3 / 5.0

V

DC

Overall regulation (load, temperature, aging)

V

OUT

-5

+5 %

Ripple and noise

50

mVp-p

Output current

I

OUT

0 1

A

DC

Isolation Output/Frame

100

V

DC

General Specifications

Parameter

Min

Typ

Max

Units

Notes

Reliability

400,000

Hrs

Full load, 25C ; MTBF per SR232 Reliability
protection for electronic equipment, method I,
case III,

Service Life

10

Yrs

Full load, excluding fans

Weight

Kgs

(Lbs)

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.

Parameter

Symbol

Min

Typ

Max

Unit

Remote ON/OFF (Needs to be pulled HI via an external resistor)

Logic High (Module ON)

I

IH

20 µA

V

IH

0.7V

DD

12 V

DC

Logic Low (Module OFF)

I

IL

1 mA

V

IL

0

0.8 V

DC


Advertising