Data Sheet
September 10, 2013

ATL010A0X43-SR Non Isolated Module 12Vdc, Programmable:

9 – 18Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

All

V

IN

-0.3 18 Vdc

Continuous

Sequencing Voltage

All

V

SEQ

-0.3 V

iN, Max

Vdc

Operating Ambient Temperature

All

T

A

-40 85 °C

(see

Thermal

Considerations

section)

Storage Temperature

All

T

stg

-55 125 °C

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

9.0

12.0

18.0

Vdc

Maximum Input Current

All

I

IN,max

7.0

Adc

(V

IN

= V

IN, min

to V

IN, max

, I

O

=I

O, max

V

O,set

= 5.5Vdc)

Input No Load Current

V

O,set

= 0.75 Vdc

I

IN,No load

40

mA

(V

IN

= 12.0Vdc, I

O

= 0, module enabled)

V

O,set

= 5.0Vdc

I

IN,No load

100

mA

Input Stand-by Current

All

I

IN,stand-by

2.0

mA

(V

IN

= 12.0Vdc, module disabled)

Inrush Transient

All

I

2

t

0.4 A

2

s

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V

IN, min

to

V

IN, max,

I

O

= I

Omax

; See Test configuration section)

All

20

mAp-p

Input Ripple Rejection (120Hz)

All

30

dB


CAUTION: These power modules can be used in a wide variety of applications ranging from simple standalone
operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, no internal fuse
has been provided. Also, extensive safety testing has shown that no external fuse is required to protect the unit.
However, it is still recommended that some type of current-limiting power source be used to protect the module and
evaluated in the end-use equipment.