Electrical specifications, General specifications – GE Industrial Solutions ATL010A0X43-SR User Manual

Page 4

Advertising
background image

Data Sheet
September 10, 2013

ATL010A0X43-SR Non Isolated Module 12Vdc, Programmable:

9 – 18Vdc input; 0.75Vdc to 5.5Vdc Output; 10A output current

LINEAGE

POWER

4

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Dynamic Load Response

(dIo/dt=2.5A/

μs; V

IN

= V

IN, nom

; T

A

=25°C)

All V

pk

100

mV

Load Change from Io= 50% to 100% of Io,max;
Co = 2x150 μF polymer capacitors

Peak Deviation

Settling Time (Vo<10% peak deviation)

All t

s

25

μs

(dIo/dt=2.5A/

μs; V

IN

= V

IN, nom

; T

A

=25°C)

All V

pk

100

mV

Load Change from Io= 100% to 50%of Io,max:
Co = 2x150 μF polymer capacitors

Peak Deviation

Settling Time (Vo<10% peak deviation)

All t

s

25

μs

General Specifications

Parameter

Min

Typ

Max

Unit

Calculated MTBF (V

IN

= V

IN, nom

, I

O

= I

O, max

, T

A

=40°C) Telecordia SR

332 Issue 1: Method 1, case 3

15,618,000 Hours

Weight

5.6 (0.2)

g (oz.)