The Power Supply Plate is available in five ratings.
Table 1 contains a listing of all GE Power Supply
Plates. All units are rated 60 Hz. Supplemental 24Vdc
input terminals are provided for systems that have
access to an external +24Vdc power supply. If this
supplemental input is connected, the assembly will
continue to pass the control power to breakers and
accessories connected to the Distribution Cable System
if the primary AC power is lost or drops below the
minimum requirement. This backup input must meet
ANSI C37.90.1 for oscillatory and fast transient surges
(the Power Supply Plate provides this protection for the
primary AC input). Additional 24Vdc output connections
are supplied for applications where +24Vdc control
power is required independent of the Distribution
Cable System (i.e., feeding an Air Circuit Breaker or
Insulated Case Breaker with microVersaTrip

®

PM/Plus or

EntelliGuard

TM

TU Trip Unit).

NOTE: THE POWER SUPPLY PLATE IS SIZED FOR A

MAXIMUM OF 20 BREAKERS. Use of the Power Supply
Plate to provide voltage sensing signals and/or +24Vdc
control power to a main Air Circuit Breaker or a main
Insulated Case Breaker with a MicroVersaTrip

®

PM/Plus

or EntelliGuard

TM

TU Trip Unit reduces the total quantity

of 20 Spectra

®

RMS Molded-Case Circuit Breakers with

microEntelliGuard

TM

or MicroVersaTrip

®

PM/Plus Trip

Units by one. The overall maximum cabling length of
the system remains 40 feet.

Table 1. Ge Power Supply Plates

Voltage

Rating

Catalog

Number

Class CC

Line Fuses # Comments

I20VAC

SPSA12O

1

2amp

1

SPSAA on mounting plate

with fuse holder

208VAC SPSA208

2amp

2

SPSAA on mounting plate

with fuse holder

240VAC SPSA240

2amp

2

SPSAA on mounting plate

with fuse holder

480VAC SPSA480

2amp

2

SPSAA on mounting plate

with fuse holder

and 480 Vac transformer

600VAC SPSA600

2amp

2

SPSAA on mounting plate

with fuse holder

and 480 Vac transformer

1

Fuse protection only in one leg – this is a line-to-neutral connection.
All other connections are line to line.

The Power Supply Plate contains six connection points.
Refer to Figures 4 and 5 for connection details and
location information. The following is a detailed list of
the Power Supply Plate connection points:

• “To Distribution Cable”
– 12-pin plug connector that mates with the 12-pin

receptacle of a Distribution Cable Harness (catalog
number SDCHA11 , SDCHA30 or SDCHA60).

• “To Voltage Conditioner”
– 12-pin plug connector that mates with the 12-

pin receptacle of a Distribution Cable Harness
(catalog number SDCHA11, SDCHA30 or SDCHA60).
For Spectra

®

RMS Molded-Case Circuit Breakers

with microEntelliGuard

TM

, MicroVersaTrip

®

PM Trip

Units, the other end of the harness MUST connect
to either a Voltage Conditioner Assembly (catalog
number SVCAA) or a Voltage Conditioner Plate
(catalog number SVCA120Y, SVCA208Y, SVCA240D,
SVCA277Y, SVCA480Y, SVCA480D or SVCA600D) for
the breaker to function properly.

• “Input Voltage”
– Two-screw terminals on the fuse block for

connection of the primary AC source.

• “Input”
– Three-screw terminal block on the Power Supply

Assembly. Use one-terminal screw for connection
of the ground (the other two-terminal screws are
factory wired to the load side of the fuse block).

• “Output to 24Vdc”
– Two-screw terminal block for optional control power

output (in lieu of using the Distribution Cable System).

• “Supplemental Input 24Vdc”
– Two-screw terminal block for connection of an

external +24Vdc power supply.

By plugging the Power Supply Plate into the Distribution
Cable System, you create system wide signals that are
available to all breakers connected to the system; a list
of those functions appears in Table 3.

Table 3. Signals available on the Distribution Cable System

by connection of the Power Supply Plate

Spectra

®

RMS

Breaker with

MicroVersaTrip

®

PM

Trip Unit

Spectra

®

RMS

Breaker with

MicroVersaTrip

®

Plus Trip Unit

Spectra

®

RMS

Breaker with

microEntelliGuard

TM

Trip Unit

control power

(+24vdc)

control power

(+24vdc)

control power

(+24vdc)

control power

(common)

control power

(common)

control power

(common)

Advertising