Ge energy, Car1612fp series rectifier, Absolute maximum ratings – GE Industrial Solutions CAR1612FP series User Manual

Page 2: Electrical specifications

Advertising
background image

GE Energy

CAR1612FP series rectifier

Input: 85Vac to 264Vac; Output: 12 Vdc @ 1600W; 3.3Vdc or 5 Vdc @ 1A

November 1, 2012

©2012 General Electric Company. All rights reserved.

Page 2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional

operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet.

Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage: Continuous

All

VIN

0

264

V

ac

Operating Ambient Temperature

All

TA

-10

60

1

°C

Storage Temperature

All

Tstg

-40

85

°C

I/O Isolation voltage to Frame (100% factory Hi-Pot tested)

All

1500

V

ac

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions.

INPUT

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operational Range

All

V

IN

85

110/230

264

V

ac

Frequency Range (ETSI 300-132-1 recommendation)

All

F

IN

47 50/60 63 Hz

Main Output Turn_OFF

All

V

IN

80

V

ac

Maximum Input Current V

IN

= 100V

ac

All I

IN

14.3
10.5

A

ac

(V

O

= V

O, set

, I

O

=I

O, max

) V

IN

= 180V

ac

Cold Start Inrush Current

All I

IN

40

A

peak

(Excluding x-caps, 25C, <10ms, per ETSI 300-132)
Efficiency [230Vac / 110Vac] 100% load

All

92.5 / 89
94.5 / 91
92.4 / 88

%

(T

amb

=25C, V

out

= 12Vdc, I

O

=I

O, max

) [230Vac / 110Vac] 50% load

[230Vac / 110Vac] 20% load
Power Factor
(Vin=230Vac, I

O

=I

O, max

)

All

PF 0.99

Holdup time

2

V

in

= 230V

ac

(Vout= 12V

dc

, Tamb 25C,

I

O

=I

O, max

) V

in

= 100V

ac

All

T 12

15

ms

Early warning prior to loss of DC output below regulation

All

2

ms

Ride through

All

T 10

ms

Leakage Current (Vin= 250Vac, Fin = 60Hz)

All

I

IN

3

mArms

Isolation Input/Output

All

3000 V

ac

Input/Frame

1500

V

ac

Output/Frame

100

V

dc

12V

dc

MAIN OUTPUT

Parameter

Device

Symbol

Min

Typ

Max

Unit

Output Power High Line Operation 180 – 264 Vac

All W

0 -

1600

W

Low Line Operation 90 – 132 Vac

0

-

1200

W

Set point

All

V

out

11.9 12.00 12.1 V

dc

Overall regulation (load, temperature, aging)

All

-3 +3

%

Ripple and noise

3

All

120

mV

p-p

Turn-ON overshoot

All

+3

%

Turn-ON delay

All

T 2

sec

1

Derated above 50C at 2.5%/C

2

12V output can decay down to 10.8V

3

Measured across a 10µf tantalum and a 0.1µf ceramic capacitors in parallel. 20MHz bandwidth

Advertising