Electrical specifications, General specifications, Continued) – GE Industrial Solutions Austin MegaLynx User Manual

Page 4

Advertising
background image

Data Sheet
April 19, 2011

Austin MegaLynx

TM

: Non-Isolated DC-DC Power Modules:

4.5 – 5.5Vdc input; 0.8 – 3.63Vdc output; 30A output current

6.0 – 14Vdc input; 0.8 – 5.5Vdc output; 25A output current

LINEAGE

POWER

4

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Dynamic Load Response

(dI

O

/dt=5A/

μs; V

IN

=V

IN

,

nom

; V

O

=3.3V; T

A

=25°C;)

Load Change from Io= 0% to 50% of I

O

,max; No

external output capacitors

Peak Deviation

ATS

V

pk

350

mV

Settling Time (V

O

<10% peak deviation)

ATS t

s

20

μs

(dI

O

/dt=5A/

μs; V

IN

=V

IN

,

nom

; V

O

=3.3V; T

A

=25°C;)

Load Change from I

O

= 50% to 0%of I

O

,

max

: No

external output capacitors

Peak Deviation

ATS

V

pk

350

mV

Settling Time (V

O

<10% peak deviation)

ATS t

s

20

μs

(dI

O

/dt=5A/

μs; V

IN

=V

IN

,

nom

; V

O

=3.3V; T

A

=25°C;)

Load Change from Io= 0% to 50% of I

O

,max; No

external output capacitors

Peak Deviation

ATH

V

pk

320

mV

Settling Time (V

O

<10% peak deviation)

ATH t

s

20

μs

(dI

O

/dt=5A/

μs; V

IN

=V

IN

,

nom

; V

O

=3.3V; T

A

=25°C)

Load Change from I

O

= 50% to 0%of I

O

,

max

: No

external output capacitors

Peak Deviation

ATH

V

pk

250

mV

Settling Time (V

O

<10% peak deviation)

ATH t

s

20

μs



General Specifications

Parameter

Min

Typ

Max

Unit

Calculated MTBF (V

IN

= V

IN, nom

, I

O

= 0.8I

O, max

, T

A

=40°C)

Telecordia SR 332 Issue 1: Method 1, case 3

3,016,040 Hours

Weight

7.4

g

Advertising