Ge energy, Car2024fp series rectifier – GE Industrial Solutions CAR2024FP series User Manual

Page 3

Advertising
background image

GE Energy

CAR2024FP series rectifier

Input: 90Vac to 264Vac; Output: 24Vdc @ 83A; 3.3Vdc or 5 Vdc @ 1A

March 28, 2013

©2012 General Electric Company. All rights reserved.

Page 3

24V

dc

MAIN OUTPUT (continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote ON/OFF delay time

All

40

ms

Turn-ON rise time (10 – 90% of V

out

)

All

60

ms

Transient response 50% step [10%-60%, 50% - 100%]

(dI/dt – 1A/

out

µs, recovery 300µs)

All

V

out

-5 +5

%V

out

Programmable range (hardware & software)

All

21

29

V

dc

Overvoltage protection, latched
(recovery by cycling OFF/ON via hardware or software)

All

30 31 32 V

dc

Output current V

in

= HL

V

in

= LL

All

I

out

0

83
50

A

dc

Current limit, Hiccup (programmable level)

All

110

130

% of FL

Active current share

All

-5

+5

% of FL

AUXILIARY OUTPUT

Parameter

Device

Symbol

Min

Typ

Max

Unit

Set point

All

V

out

3.3

/

5.0

V

dc

Overall regulation (load, temperature, aging)

All

V

out

-5 +5 %

Ripple and noise

All

50

mVp-p

Output current

All

I

out

0 1

A

dc

Overload protection -

Overvoltage protection

Isolation Output/Frame

All

100

V

dc

Environmental, Reliability

Parameter

Min

Typ

Max

Units

Notes

Ambient Temperature
Operating
Altitude Operating
Power Derating

-10

4

50

2250/7.4k

2.5
2.0

°C

m / ft

%/°C

C/1000 ft


Air inlet from sea level to 5,000 feet.

51°C to 70C
Above 5,000 ft

Storage
Altitude non-operating

-40

85

8200/30k

°C

m / ft

Acoustic noise

55

dbA

Full load

Over-temperature Protection

125/110

°C

Shutdown / restart

Humidity Operating
Storage

30
10

95

95

%

Relative humidity, non-condensing

Shock and Vibration acceleration

6

Grms

NEBS GR-63-CORE, Level 3, 20 -2000Hz, min 30 minutes

Earthquake Rating

4

Zone

NEBS GR-63-CORE, all floors, Seismic Zone 4 Designed

and tested to meet NEBS specifications.

Reliability

400,000

Hrs

Full load, 25C ; MTBF per SR232 Reliability protection
for electronic equipment, method I, case III,

Service Life

10

Yrs

Full load, excluding fans


4

Designed to start at an ambient down to -40°C; meet spec after  30 min warm up period, may not meet operational limits below -10°C.