General specifications, Feature specifications, Tlynx – GE Industrial Solutions TLynx User Manual

Page 4

Advertising
background image

Data Sheet
August 13, 2013

TLynx

TM

: Non-isolated DC-DC Power Modules:

2.4 – 5.5Vdc input; 0.6Vdc to 3.63Vdc output; 20A output current

LINEAGE

POWER

4

General Specifications

Parameter

Min

Typ

Max

Unit

Calculated MTBF (I

O

=0.8I

O, max

, T

A

=40°C) Telcordia Issue 2 Method

1 Case 3

7,868,128 Hours

Weight

6.03 (0.21)

g (oz.)

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

On/Off

Signal

Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to GND)

Device is with suffix “4” – Positive Logic (See Ordering
Information)

Logic High (Module ON)

Input High Current

All

I

IH

10 µA

Input High Voltage

All

V

IH

V

IN

-0.8

V

IN,max

V

Logic Low (Module OFF)

Input Low Current

All

I

IL

0.3 mA

Input Low Voltage

All

V

IL

-0.2

0.3 V

Device Code with no suffix – Negative Logic (See Ordering
Information)

(On/OFF pin is open collector/drain logic input with

external pull-up resistor; signal referenced to GND)

Logic High (Module OFF)

Input High Current

All

I

IH

― 2 mA

Input High Voltage

All

V

IH

V

IN

– 1.6

V

IN, max

Vdc

Logic Low (Module ON)

Input low Current

All

I

IL

― 1 mA

Input Low Voltage

All

V

IL

-0.2

V

IN

– 1.6

Vdc

Turn-On Delay and Rise Times

(V

IN

=V

IN, nom

, I

O

=I

O, max ,

V

O

to within ±1% of steady state)

Case 1: On/Off input is enabled and then input power is
applied (delay from instant at which V

IN

= V

IN, min

until

V

o

= 10% of V

o, set

)

All Tdelay ― 2 ― msec

Case 2: Input power is applied for at least one second
and then the On/Off input is enabled (delay from instant
at which Von/Off is enabled until V

o

= 10% of V

o, set

)

All Tdelay ― 2 ― msec

Output voltage Rise time (time for V

o

to rise from

10% of Vo, set to 90% of Vo, set)

All Trise

― 5 ― msec

Output voltage overshoot (T

A

= 25

o

C

3.0

% V

O,

V

IN

= V

IN, min

to V

IN, max

,I

O

= I

O, min

to I

O, max

)

With

or

without

maximum

external

capacitance

Over Temperature Protection

All

T

ref

144 °C

(See Thermal Considerations section)

Sequencing Delay time

Delay from V

IN, min

to application of voltage on SEQ pin

APTH

Ts

EQ-delay

10

msec

Tracking Accuracy (Power-Up: 2V/ms)

APTH

V

SEQ

–V

o

100 mV

(Power-Down: 2V/ms)

APTH

V

SEQ

–V

o

100 mV

(V

IN, min

to V

IN, max

; I

O, min

to I

O, max

V

SEQ

< V

o

)

Advertising