: Non-isolated DC-DC Power Modules:

2.4 – 5.5Vdc input; 0.6Vdc to 3.63Vdc output; 20A output current


LINEAGE

POWER

5

Feature Specifications (continued)

Parameter

Device

Symbol

Min

Typ

Max

Units

Input Undervoltage Lockout

Turn-on Threshold

All

2.2 Vdc

Turn-off Threshold

All

2.0 Vdc

Hysteresis All

0.08 0.2