GE Industrial Solutions AF-650 GP Resolver Module User Manual

Af-650 gp

Advertising
background image

AF-650 GP

TM

1

Resolver Option Module (OPCRES)

OPCRES Resolver Option is used for interfacing resolver motor
feedback to AF-650 GP

TM

. Resolvers are used basically as

motor feedback device for Permanent Magnet brushless
synchronous motors.

Resolver specifications:
Resolver poles

Par. RS-50: 2 *2

Resolver Input Voltage

Par. RS-51: 2.0-8.0 Vrms *7.0 Vrms

Resolver Input Frequency Par. RS-52: 2-15 kHz *10.0 kHz
Transformation ratio

Par. RS-53: 0.1-1.1 *0.5

Secondary input voltage

Max. 4 Vrms

Secondary load

App. 10 k

NOTE!
The resolver option Module can only be used with rotor-supplied resolver types.
Stator-supplied resolvers cannot be used.

When the Resolver option is ordered separately the kit includes:

Resolver Option Module (OPCRES)

Larger keypad cradle and terminal cover for Unit Size 12, 13, and 23 drives (230V to 10HP & 460/575V

to 20HP)

Conf igure Resolver Option Module in parameter group RS-## and with par. EC-60 Feedback Direction & EC-61
Feedback Signal Monitoring.

The Resolver Option Module supports a various number of resolver types.

Advertising