List of figures – GE Industrial Solutions ProTrip Conversion Kits AK-50, AKU-50, AKS-50, AKT-50, AK-75, and AK-100 User Manual

Page 3

Advertising
background image

LIST OF FIGURES

1. Relocation and remounting of the W and X relays........................................................................................... 5

2. New X and W relay mounting brackets ............................................................................................................ 5

3.

Flux

shifter assembly........................................................................................................................................ 6

4. Pattern for flux shifter mounting holes in the side frame.................................................................................. 6

5. Flux shifter assembly mounted to the side frame. ........................................................................................... 6

6. Location of new hole in the flux shifter base. ................................................................................................... 7

7. Locations of new holes for mounting the OFLO terminal block. ...................................................................... 7

8. Existing trip paddles to be removed. ................................................................................................................ 8

9.

Installing

the new trip paddle............................................................................................................................ 8

10.

Adjusting

the flux shifter. .................................................................................................................................. 8

11. Mounting hole drill pattern for the trip unit mounting plate. .............................................................................. 9

12. Trip unit mounting plate attached to the breaker front channel. ...................................................................... 9

13. Trip unit mounting bracket attached to the mounting plate. ............................................................................. 9

14. Actuator bracket attached to the left pole link. ............................................................................................... 10

15. Drill pattern for actuator bracket mounting holes. .......................................................................................... 10

16. Existing EC trip devices before removal. ....................................................................................................... 11

17. Removal of EC trip devices. ........................................................................................................................... 11

18. Parts provided for CT installation per pole. .................................................................................................... 12

19. CT post mounted in the breaker back frame.................................................................................................. 12

20.

CT

installation completed.. ............................................................................................................................. 12

21. Phase sensor installation on AK-75 & AK-100 breakers. .............................................................................. 13

22. Attaching the trip unit to the mounting plate................................................................................................... 14

23. Trip unit mounted on the breaker. .................................................................................................................. 14

24. Fourth-wire terminal board installation on AK-50 & AKS-50 stationary breakers. ......................................... 15

25. Fourth-wire disconnect installed on AK-50 & AKS-50 draw-out breakers. .................................................... 16

26. Fourth-wire disconnect assembly for AKD-5 or AKD-6 equipment................................................................ 16

27. Fourth-wire disconnect assembly for AKD equipment. .................................................................................. 16

28. K-75 & AK-100 back frame conversion. ......................................................................................................... 17

29. Outline of the neutral sensor for AK-50 breakers........................................................................................... 18

30. Outline of the neutral sensor for AK-75 and AK-100 breakers ...................................................................... 19

31. AK-50 & AKS-50 fourth-wire disconnect for AKD. ......................................................................................... 20

32. AK-75 & AK-100 fourth-wire disconnect for AKD-5 & AKD-6. ....................................................................... 20

33.

AK-100

fourth-wire disconnect for AKD. ........................................................................................................ 20

34. AK-50 & AKS-50 fourth-wire disconnect for AKD. ......................................................................................... 21

35.

Fourth-wire

disconnect for AKD-5 & AKD-6................................................................................................... 21

36. Cabling diagram for ProTrip™ trip units with ground fault on four-wire loads. .............................................. 24