Emc considerations, Lineage power 12 – GE Industrial Solutions EVW010A0B Series (Eighth-Brick) User Manual

Page 12

Advertising
background image

Data Sheet

September 4, 2013

EVW010A0B Series Power Modules

36 – 75Vdc Input; 12.0Vdc Output; 10A Output Current

LINEAGE

POWER

12

EMC Considerations

The circuit and plots in Figure 25 shows a suggested configuration to meet the conducted emission limits of EN55022
Class B.

0

10

20

30

40

50

60

70

80

Level [dBµV]

150k

300k

500k

1M

2M

3M

4M 5M

7M

10M

30M

Frequency [Hz]

x

x

x

x

x

x

x x

MES CE0615090841_fin QP
MES CE0615090841_pre PK

0

10

20

30

40

50

60

70

80

Level [dBµV]

150k

300k

500k

1M

2M

3M

4M 5M

7M

10M

30M

Frequency [Hz]

+

+ +

+

+

+

+ +

MES CE0615090841_fin AV
MES CE0615090841_pre AV

Figure 25. EMC Considerations

For further information on designing for EMC compliance, please refer to the FLT007A0 data sheet (DS05-028).