Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Nominal Output Voltage Set-point

All V

O, set

11.76 12.0 12.24 V

dc

V

IN

=V

IN, min

, I

O

=I

O, max

, T

A

=25°C)

Output Voltage

All

V

O

-3.0

+3.0 %

V

O, set

(Over all operating input voltage, resistive load,
and temperature conditions until end of life)

Output Regulation

Line (V

IN

=V

IN, min

to V

IN, max

) All

0.2 %

V

O, set

Load (I

O

=I

O, min

to I

O, max

)

All

 0.2

%

V

O, set

Temperature (T

ref

=T

A, min

to T

A, max

) All

1.0 %

V

O, set

Output Ripple and Noise on nominal output

(V

IN

=V

IN, nom

,I

O

= I

O, max

, T

A

=T

A, min

to T

A, max

)

RMS (5Hz to 20MHz bandwidth)

All

30 mV

rms

Peak-to-Peak (5Hz to 20MHz bandwidth)

All

100 mV

pk-pk

External Capacitance

All

C

O

100

2,000

μF

Output Current

All

I

o

0

10 A

dc

Output Current Limit Inception (Hiccup Mode )

All

I

O, lim

105 115 130 % I

o

(V

O

= 90% of V

O, set

)

Output Short-Circuit Current

All I

O, s/c

3 5

A

rms

(V

O

≤250mV) ( Hiccup Mode )

Efficiency All

η 93.5 %

V

IN

= V

IN, nom

, T

A

=25°C

I

O

=I

O, max ,

V

O

= V

O,set

Switching Frequency (Input ripple is ½ f

sw

) All

f

sw

370 kHz

Dynamic Load Response

(dIo/dt=0.1A/

s; V

IN

= V

IN, nom

; T

A

=25°C)

Load Change from Io= 50% to 75% or 25% to
50% of Io,max;

Peak Deviation

All

V

pk

3

% V

O, set

Settling Time (Vo<10% peak deviation)

All t

s

200

s

(dIo/dt=1A/

s; V

IN

= V

IN, nom

; T

A

=25°C)

Load Change from Io= 50% to 75% or 25% to
50% of Io,max;

Peak Deviation

All

V

pk

5

% V

O, set

Settling Time (Vo<10% peak deviation)

All t

s

200

s

Isolation Specifications

Parameter

Device

Symbol

Min

Typ

Max

Unit

Isolation Capacitance

All

C

iso

1000

pF

Isolation Resistance

All

R

iso

10

MΩ

I/O Isolation Voltage (100% factory Hi-pot tested)

All

All

2250 V

dc

General Specifications

Parameter

Device

Symbol

Min

Typ

Max

Unit

Calculated Reliability based upon Telcordia SR-
332 Issue 2: Method

I

Case 3 (I

O

=80%I

O, max

,

T

A

=40°C, airflow = 200 lfm, 90% confidence)

All FIT

323.4

10

9

/Hours

All MTBF

3,092,530

Hours

Weight (Open Frame)

All

19

(0.67)

g

(oz.)

Weight (with Heatplate)

All

32

(1.13)

g

(oz.)