Ehhd024a0a series: dc-dc converter power module, Datasheet, 18 to 75v – GE Industrial Solutions EHHD024A0A HAMMERHEAD Series User Manual

Page 12: Input; 5v, Pb-free reflow profile, Post solder cleaning and drying considerations

Advertising
background image

GE

Datasheet

EHHD024A0A Series: DC-DC Converter Power Module

18 to 75V

dc

Input; 5V

dc

, 24A, 120W Output

February 28, 2014

©2014 General Electric Corporation. All rights reserved.

Page 12

RE

FLOW T

EMP

C)

REFLOW TIME (S)

Figure 24. Reflow Profile for Tin/Lead (Sn/Pb) process.

MAX T

EMP

SO

LDE

R (

°C)

Figure 25. Time Limit Curve Above 205

o

C for Tin/Lead

(Sn/Pb) process

Pb-free Reflow Profile

Power Systems will comply with J-STD-015 Rev. D
(Moisture/Reflow Sensitivity Classification for Nonhermetic
Solid State Surface Mount Devices) for both Pb-free solder
profiles and MSL classification procedures. This standard

provides a recommended forced-air-convection reflow
profile based on the volume and thickness of the package
(table 4-2). The suggested Pb-free solder paste is Sn/Ag/Cu
(SAC). The recommended linear reflow profile using
Sn/Ag/Cu solder is shown in Figure 26.

Figure 26. Recommended linear reflow profile using
Sn/Ag/Cu solder.

Post Solder Cleaning and Drying Considerations

Post solder cleaning is usually the final circuit-board

assembly process prior to electrical board testing. The result
of inadequate cleaning and drying can affect both the
reliability of a power module and the testability of the

finished circuit-board assembly. For guidance on
appropriate soldering, cleaning and drying procedures, refer
to GE Board

Mounted Power Modules: Soldering and Cleaning Application
Note (AN04-001).












0

50

100

150

200

250

300

P reheat zo ne
max 4

o

Cs

-1

Soak zone
30-240s

Heat zo ne
max 4

o

Cs

-1

P eak Temp 235

o

C

Co oling
zone
1-4

o

Cs

-1

T

lim

above

205

o

C

200

205

210

215

220

225

230

235

240

0

10

20

30

40

50

60

Per J-STD-020 Rev. D

0

50

100

150

200

250

300

Reflow Time (Seconds)

Reflow Temp (°C)

Heating Zone
1°C/Second

Peak Temp 260°C

* Min. Time Above 235°C

15 Seconds

*Time Above 217°C

60 Seconds

Cooling
Zone

Advertising