GE Industrial Solutions Finger Clusters User Manual

Page 8

Advertising
background image

7

Finger Clusters (Assemblies) Accessory Manual DEH-41533 02/12

Figure 6. Fingers or Clusters, Mechanical View, and Notes (continued)

Notes:

1. With text fixtures between upper and lower

pairs of Item 2, tighten Item 11 until force on
fixture is 95 ± 10 lbs. [422.6 ± 44.2 N] and test
fixture thickness is 0.500 inches [12.70 mm].

2. With 0.500 inches [12.70 mm] thick test bar

between upper and lower pairs of Item 2, the
clearance between all fingers (Item 2 and
Item 4) should be 0.020 inches [0.50 mm]
minimum.

3. With text fixture or test bar removed, the gap

between the fingers (Item 2) should be
0.400 inches [10.20 mm].

4. Distance "D" range is 0.766 to 0.797 inches

[19.50 to 20.24 mm]. Note that no bar is
inserted between the fingers when setting
this dimension.

5. See higher ASM. View for proper orientation

of parts.

Advertising