12v austinlynx, 10a: non-isolated dc-dc power modules,programmable, Data sheet – GE Industrial Solutions 12V AustinLynx 10A User Manual
Page 4: Electrical specifications, General specifications
GE
Data Sheet
12V AustinLynx
TM
10A: Non-Isolated DC-DC Power Modules,Programmable
10Vdc –14Vdc input; 0.75Vdc to 5.5Vdc output; 10A Output Current
May 8, 2013
©2013 General Electric Company. All rights reserved.
Page 4
Electrical Specifications
(continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
Dynamic Load Response
(dIo/dt=2.5A/
μs; V V
IN
= V
IN, nom
; T
A
=25°C)
All V
pk
⎯
100
⎯
mV
Load Change from Io= 50% to 100% of Io,max;
Co = 2x150 μF polymer capacitors
Peak Deviation
Settling Time (Vo<10% peak deviation)
All t
s
⎯
25
⎯
μs
(dIo/dt=2.5A/
μs; V
IN
= V
IN, nom
; T
A
=25°C)
All V
pk
⎯
100
⎯
mV
Load Change from Io= 100% to 50%of Io,max:
Co = 2x150 μF polymer capacitors
Peak Deviation
Settling Time (Vo<10% peak deviation)
All t
s
⎯
25
⎯
μs
General Specifications
Parameter
Min
Typ
Max
Unit
Calculated MTBF (I
O
=I
O, max
, T
A
=25°C) 4,400,000
Hours
Weight
⎯
5.6 (0.2)
⎯
g (oz.)