HAZARDOUS VOLTAGE
Disconnect all power before working on equipment.
Electrical shock will cause severe injury or death.

TENSION DANGEREUSE
Coupez l’alimentation avant travailler sur le produit.
Electrocution peut causer de severes blessures ou la mort.
Description
The GE CR460 Series is a magnetically operated lighting
contactor, and is available in either an open or an enclosed
form. These contactors are field configurable for up to twelve
poles, with a maximum of eight normally closed “NC” poles.

Figure – 1 Mechanically Held Contactor

1

MAIN BASE

1.1 Description
The base of the lighting contactor (see Figure 1) has provisions
to accept power poles at positions “1” to “6”. Provisions are
also provided for up to 2 “NO” and 2 “NC” auxiliary contacts.

1.2 Installation
1. Remove all packing material from the base and all the kits.
2. Contactor must be mounted in the vertical position on a

sturdy support.

3. Additional over-current protection may be required. Refer

to the National Electrical Code or local electrical code as
required.

4. Refer to Table D on page 3 for the wire size and the

required torque for the coil terminals.

2

POWER POLES: CR460XP31 / 32

2.1 Description
Power poles are available in both single pole (CR460XP31)
and double pole (CR460XP32) versions. A maximum of
twelve poles may be installed on the base. Positions “1” to “4”
on the base can be configured as either normally open “NO” or
“NC” while positions “5” and “6” can be configured as “NO”
only.

2.2 Removal and Conversion of Power Poles
1. If installed ensure that all power is disconnected.
2. For multiple possible configurations of the power pole,

refer to the Table A below.

Table A

3. Remove block by pulling the clip as shown (see Figure 2).

Rotate block 180 degrees to convert from NO to NC.

Figure – 2

2.3 Installation of Power Poles
1. Check moving carrier to assure free movement
2. Install the block by sliding foot into slot; pull the clip, and

position block onto base. Release the clip.

DEH-40460 Instruction Sheet

WARNING

!

!

CR460 LIGHTING CONTACTOR SERIES

GE Lighting Contactors

# of NC Contacts desired (3)

0

1

2

3

4

5

6

7

8

0

20

30

40

50

60

70

80

1

11

30

31

50

51

70

71

90

2

20

30

40

50

60

70

80

90

B0

3

30

31

50

51

70

71

90

91

CO

4

40

50

60

70

80

90

B0

C0

D0

5

50

51

70

71

90

91

C0

6

60

70

80

90

B0

C0

D0

7

70

71

90

91

CO

8

80

90

B0

CO

D0

9

90

91

CO

10

B0

CO

DO

11

C0

12

D0

# of NO Contacts desired (4)

Standard Catalog # Digits

CR463L70AJA0

NO

NC

Main Base

NO Aux.

Contact

NC Aux.

Contact

Advertising