12v tlynx, 20a: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12V TLynx 20A User Manual
Page 23
Advertising
GE
Data Sheet
12V TLynx
TM
20A: Non-Isolated DC-DC Power Modules
4.5Vdc –14Vdc input; 0.69Vdc to 5.5Vdc output; 20A Output Current
May 2, 2013
©2013 General Electric Company. All rights reserved.
Page 23
Recommended Pad Layout
Dimensions are in millimeters and (inches).
Tolerances: x.xx in.
± 0.02 in. (x.x mm ± 0.5 mm) [unless otherwise indicated]
x.xxx in
± 0.010 in. (x.xx mm ± 0.25 mm)
PIN
FUNCTION
1 ON/OFF
2 VIN
3 SEQ
4 GND
5 VOUT
6 TRIM
7 S+
8 S-
9 PGOOD
10 SYNC