12v tlynx, 20a: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12V TLynx 20A User Manual

Page 7: Characteristic curves

Advertising
background image

GE

Data Sheet

12V TLynx

TM

20A: Non-Isolated DC-DC Power Modules

4.5Vdc –14Vdc input; 0.69Vdc to 5.5Vdc output; 20A Output Current

May 2, 2013

©2013 General Electric Company. All rights reserved.

Page 7

Characteristic Curves

The following figures provide typical characteristics for the 12V TLynx

TM

at 0.69Vo and at 25

o

C.

EFFICI

EN

C

Y,

η

(%)

70

75

80

85

90

0

5

10

15

20

Vin=10V

Vin=7V

Vin=5V

OUT

PUT

CURR

ENT,

Io

(A)

4

6

8

10

12

14

16

18

20

22

35

45

55

65

75

85

95

105

Standard Part

(85°C)

Ruggedized (D)

Part (105

°

C)

NC

0.5m/s

(100LFM)

1m/s

(200LFM)

2m/s

(400LFM)

OUTPUT CURRENT, I

O

(A)

AMBIENT TEMPERATURE, T

A

O

C

Figure 1. Converter Efficiency versus Output Current.

Figure 2. Derating Output Current versus Ambient
Temperature and Airflow.

OUT

PU

T VOLTAG

E

V

O

(V

) (1

0m

V/

di

v)

OUT

PU

T CURRE

NT,

OU

TP

U

T V

O

LT

AGE

I

O

(A

) (

5Adi

v)

V

O

(V

) (200

mV/div

)

TIME, t (1

μs/div)

TIME, t (20

μs /div)

Figure 3. Typical output ripple and noise (V

IN

= 12V, I

o

= I

o,max

). Figure 4. Transient Response to Dynamic Load Change from

0% to 50% to 0%.

O

N

/O

FF

VO

LT

AG

E

O

U

TPU

T

VO

LTA

G

E

V

ON

/O

FF

(V

) (5

V/

di

v)

V

O

(V) (

200m

V/

di

v)

O

U

TP

UT VO

LTA

G

E

I

N

PU

T VO

LTA

G

E

V

O

(V

) (

1V

/div)

V

IN

(V

) (5V/

div

)

TIME, t (2 ms/div)

TIME, t (1 ms/div)

Figure 5. Typical Start-up Using On/Off Voltage (I

o

= I

o,max

).

Figure 6. Typical Start-up Using Input Voltage (V

IN

= 10V, I

o

=

I

o,max

).

Advertising