5 of 10, Communication signals: j1 connector, Communication signals: j2 connector – GE Industrial Solutions J85480S1, L1 – L14 Compact Power Line Shelves User Manual

Page 5: Cannot be used in split shelves l7, l9, l14)

Advertising
background image

5 of 10

COMPACT POWER LINE SHELVES – MODEL J85480S1

Communication Signals: J1 Connector

Pin out

Control Interface Connection (J1 - AMP 499913-9)

Pin

Signal

Pin

Signal

1 POWER_CAP_4 21 Enable

side

A

2 POWER_CAP_3 22 5VA

3 POWER_CAP_2 23 Logic_GRD

4 POWER_CAP_1 24 Interrupt_1

5 MOD_PRES_4

25 Reset

6

MOD_PRES_3

26

Enable Side B

7 MOD_PRES_2

27 Spacing

8 MOD_PRES_1

28 Spacing

9 PFW_4

29 RS_485_Select

10 PFW_3

30 Shelf_Addr_A

11 PFW_2

31 Shelf_Addr_B

12 PFW_1

32 Shelf_Addr_C

13 SCL_0

33 Shelf_Addr_D

14 SCL_1

34 Shelf_Addr_E

15 SDA_0

35 Shelf_Addr_F

16 SDA_1

36 Shelf_Addr_G

17 OTW

37 Protocol_S

18 Margin

38 RS-485+

19 Fault

39 RS_485-

20 Interrupt_0

40 Ishare

Communication Signals: J2 Connector

( cannot be used in split shelves L7, L9, L14)

Pin out

Multi-shelf Connection (J2 – AMP 499913-8)

Pin

Signal

Pin

Signal

1

PFW_4

18

Enable Side B

2 PFW_3

19 Spacing

3 PFW_2

20 Spacing

4 PFW_1

21

RS_485_Select

5 SCL_0

22

Shelf_Addr_B

6 SCL_1

23

Shelf_Addr_C

7 SDA_0

24

Shelf_Addr_D

8 SDA_1

25

Shelf_Addr_E

9 OTW

26

Shelf_Addr_F

10 Margin

27

Shelf_Addr_G

11 Fault

28

Shelf_Addr_H

12 Interrupt_0

29 Protocol_S

13 Enable

side

A 30

RS-485+

14 5VA

31

RS_485-

15 Logic_GRD

32

Ishare

16 Interrupt_1

33

Spare

17 Reset

34 Spare

Note: Shelf addressing, current share and RS485 communications are all referenced to the most negative
power output Vout(-) of the shelf. For paralleled shelves the Vout(-) terminations must be tied together in order
to ensure proper operation of these functions. Modules could get damaged if this connection is not made. .

Advertising