Ehhd036a0f series: dc-dc converter power module, Datasheet, 18 to 75v – GE Industrial Solutions EHHD036A0F HAMMERHEAD Series User Manual

Page 9: Input; 3.3v, Thermal considerations (continued)

Advertising
background image

GE

Datasheet

EHHD036A0F Series: DC-DC Converter Power Module

18 to 75V

dc

Input; 3.3V

dc

, 36A, 120W Output

February 28, 2014

©2014 General Electric Corporation. All rights reserved.

Page 9

Thermal Considerations (continued)


The thermal reference points, T

ref1

and T

re21

,

used in the

specifications for open frame modules are shown in Figure

13. For reliable operationthese temperatures should not
exceed 122° and 123

O

C respectively.

Figure 13. T

ref

Temperature Measurement Locations for

Open Frame Module.


The thermal reference point, T

ref

,

used in the specifications

for modules with heatplate is shown in Figure 14. For
reliable operation this temperature should not exceed 105

O

C.

Figure 14. T

ref

Temperature Measurement Location for

Module with Heatplate.

Heat Transfer via Convection

Increased airflow over the module enhances the heat

transfer via convection. Derating curves showing the
maximum output current that can be delivered by
each module versus local ambient temperature (T

A

)

for natural convection and up to 3m/s (600 ft./min) forced
airflow are shown in Figures 15 - 20.

Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-Mounted
Power Modules” for a detailed discussion of thermal

aspects including maximum device temperatures.

OUT

PUT

CUR

REN

T,

I

O

(A

)

AMBIENT TEMEPERATURE, T

A

(

o

C

)

Figure 15. Output Current Derating for the Open Frame

Module; Airflow in the Transverse Direction from V

out

(-) to

V

out

(+); V

IN

=48V, V

O

=3.3V.

O

U

TP

UT CURR

ENT, I

O

(A

)

AMBIENT TEMEPERATURE, T

A

(

o

C

)

Figure 16. Output Current Derating for the Module with
Heatplate; Airflow in the Transverse Direction from V

out

(-)

to V

out

(+);V

IN

=48V, V

O

=3.3V.

T

ref

1

T

ref

2

AIRFLOW

Figure 13. For reliable operation and

should not exceed 122°C and 123°C .

T

ref

1

T

ref

2

0

4

8

12

16

20

24

28

32

36

30

40

50

60

70

80

90

NC

100LFM
(0.5m/s)

200LFM
(1.0m/s)

400LFM
(2.0m/s)

0

4

8

12

16

20

24

28

32

36

30

40

50

60

70

80

90

NC

100LFM
(0.5m/s)

200LFM
(1.0m/s)

400LFM
(2.0m/s)