Data Sheet

October 5, 2009

FNW500R Power Modules; DC-DC Converters

36 – 75 Vdc Input; 28Vdc Output; 500W Output


LINEAGE

POWER

3

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Output Voltage Set-point
(V

IN

=V

IN,nom

, I

O

=I

O, max

, T

c

=25°C)

All

V

O, set

27.5 28 28.5 V

dc

Output Voltage
(Over all operating input voltage, resistive load,
and temperature conditions until end of life)

All

V

O

27.15

28.85

V

dc

Output

Regulation

Line (V

IN

=V

IN, min

to V

IN, max

) All

0.05 0.2 %Vo

Load (I

O

=I

O, min

to I

O, max

) All

0.05 0.2

%Vo

Temperature (T

c

= -40ºC to +100ºC)

All

100 300 mV

Output Ripple and Noise on nominal output

(V

IN

=V

IN, nom

and I

O

=I

O, min

to I

O, max

)

RMS (5Hz to 20MHz bandwidth)

All

80 mV

rms

Peak-to-Peak (5Hz to 20MHz bandwidth)

All

140

300

mV

pk-pk

External Capacitance
Note: use a minimum 470uF output capacitor. If
the ambient temperature is less than -20

o

C, use

more than 3 of recommended minimum
capacitors.

All C

O, max

470 1000 5000

μF

Output Current

All

I

o

1.8 18

Adc

Output Current Limit Inception

All

I

O, lim

19

22

25.2

Adc

Efficiency
V

IN

=V

IN, nom

, T

c

=25°C

I

O

=I

O, max ,

V

O

= V

O,set

All

η

91

%

Switching Frequency

f

sw

300

kHz

Dynamic Load Response

(

ΔIo/Δt=1A/10μs; V

in

=V

in

,nom; T

c

=25°C;

Tested with a 470 μF aluminum and a 10 µF

ceramic capacitor across the load.)

Load Change from Io= 50% to 75% of Io,max:

Peak Deviation

Settling Time (Vo<10% peak deviation)

All

V

pk

t

s

__

3
2

__

%V

O, set

ms

Load Change from Io= 25% to 50% of Io,max:

Peak Deviation

V

pk

__ 3 __

%V

O, set

Settling Time (Vo<10% peak deviation)

t

s

2

ms

Isolation Specifications

Parameter

Symbol

Min

Typ

Max

Unit

Isolation Capacitance

C

iso

1500

pF

Isolation Resistance

R

iso

10

MΩ

General Specifications

Parameter

Device

Symbol

Min

Typ

Max

Unit

FIT 402

10

9

/Hours

Calculated Reliability based upon Telcordia SR-
332 Issue 2: Method

I

Case 3 (I

O

=80%I

O, max

,

T

A

=40°C, airflow = 200 lfm, 90% confidence)

All

MTBF 2,487,326 Hours

150

g

Weight All

5.3 oz.

Advertising