Feature specifications – GE Industrial Solutions FNW500R Series User Manual

Page 4

Advertising
background image

Data Sheet

October 5, 2009

FNW500R Power Modules; DC-DC Converters

36 – 75 Vdc Input; 28Vdc Output; 500W Output

LINEAGE

POWER

4

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent),

Refer to remote on/off description and Figure 11.

Remote On/Off Current – Logic ON

All

I

on/off

1.0

5.0 mA

Remote On/Off Current – Logic OFF

All

I

on/off

50

μA

Turn-On Delay and Rise Times

(Vin=Vin,nom, I

O

=I

O, max

, 25C)

Case1:

T

delay

=

Time until VO = 10% of Vo,set from

application of Vin with Remote On/Off set to ON,

All

T

delay

60 75

100 ms

Case2: T

delay

=

Time until VO = 10% of Vo,set from

application of Remote On/Off from Off to On with Vin
already applied for at least one second.

All

T

delay

5

ms

T

rise

= time for V

O

to rise from 10% of V

O,set

to 90%

of V

O,set

.

All

T

rise

25

ms

Output Voltage Overshoot

3

% V

O, set

(I

O

=80% of I

O, max

, T

A

=25°C)

Output Voltage Adjustment
(See Feature Descriptions):





Output Voltage Remote-sense Range
(only for No Trim or Trim down application )

All V

sense

__

__

2 %V

o,nom

Output Voltage Set-point Adjustment Range (trim)

All

V

trim

60

__

110 %V

o,nom

Output Overvoltage Protection

All

V

O, limit

32

38 V

Over Temperature Protection

All T

ref

106

°C

(See Feature Descriptions)

Input Under Voltage Lockout

V

IN, UVLO

Turn-on Threshold

All

35 36 V

Turn-off Threshold

All

30 31 V

Hysteresis

All

4 V

Input Over voltage Lockout

V

IN, OVLO

Turn-on Threshold

All

76

78

V

Turn-off Threshold

All

79

80

V

Hysteresis

All

---

4 --- V








Advertising