Data Sheet
September 10, 2013

Austin SuperLynx II

TM

SMT Non-isolated Power Modules:

2.4 – 3.63Vdc input; 0.75Vdc to 2.0Vdc Output; 20A output current

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

All

V

IN

-0.3 4.0 Vdc

Continuous

Sequencing Voltage

All

V

SEQ

-0.3 V

iN, Max

Vdc

Operating Ambient Temperature

All

T

A

-40 85 °C

(see

Thermal

Considerations

section)

Storage Temperature

All

T

stg

-55 125 °C

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

V

O,set

≤ V

IN

– 0.5V

V

IN

2.4

3.63 Vdc

Maximum Input Current

All

I

IN,max

20.0

Adc

(V

IN

= V

IN, min

to V

IN, max

, I

O

=I

O, max

V

O,set

= 3.3Vdc)

Input No Load Current

V

O,set

= 0.75Vdc

I

IN,No load

80

mA

(V

IN

= 2.4Vdc, I

O

= 0, module enabled)

V

O,set

= 1.8Vdc

I

IN,No load

110

mA

Input Stand-by Current

All

I

IN,stand-by

1.5

mA

(V

IN

= 2.4Vdc, module disabled)

Inrush Transient

All

I

2

t

0.1 A

2

s

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V

IN, min

to

V

IN, max,

I

O

= I

Omax

; See Test configuration section)

All

100

mAp-p

Input Ripple Rejection (120Hz)

All

30

dB

CAUTION: This power module is not internally fused.

This power module can be used in a wide variety of applications, ranging from simple standalone operation to being
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included. This power
module meets all safety agency requirements without presence of an input fuse. However, to achieve maximum
safety and system protection, an input line fuse may be used. Based on the information provided in this data sheet
on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the
fuse manufacturer’s data sheet for further information.