Characteristic curves, Austin minilynx, Continued) – GE Industrial Solutions Austin Minilynx SMT User Manual

Page 9

Advertising
background image

Data Sheet
September 10, 2013

Austin MiniLynx

TM

SMT Non-isolated Power Modules:

2.4 – 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 3A output current


LINEAGE

POWER

9

Characteristic Curves

(continued)

The following figures provide thermal derating curves for the Austin MiniLynx

TM

SMT modules.

OUT

P

UT

C

URR

E

N

T, Io

(

A

)

0

0.5

1

1.5

2

2.5

3

3.5

20

30

40

50

60

70

80

90

0 LFM

OUT

P

UT

C

URR

E

N

T, Io

(

A

)

0

0.5

1

1.5

2

2.5

3

3.5

20

30

40

50

60

70

80

90

0 LFM

AMBIENT TEMPERATURE, T

A

O

C AMBIENT

TEMPERATURE,

T

A

O

C

Figure 19. Derating Output Current versus Local
Ambient Temperature and Airflow (

V

IN

= 5.0,

Vo=3.3Vdc).

Figure 22. Derating Output Current versus Local
Ambient Temperature and Airflow (V

IN

= 3.3dc,

Vo=2.5 Vdc).

O

U

T

P

UT

CU

RRE

NT

, Io

(A

)

0

0.5

1

1.5

2

2.5

3

3.5

20

30

40

50

60

70

80

90

0 LFM

0

0.5

1

1.5

2

2.5

3

3.5

20

30

40

50

60

70

80

90

0 LFM

AMBIENT TEMPERATURE, T

A

O

C

Figure 20. Derating Output Current versus Local
Ambient Temperature and Airflow (V

IN

= 5.0Vdc,

Vo=1.8 Vdc).

Figure 23. Derating Output Current versus Local
Ambient Temperature and Airflow (V

IN

= 3.3dc,

Vo=1.2 Vdc).

O

U

TPU

T

CUR

RE

NT,

Io

(A

)

0

0.5

1

1.5

2

2.5

3

3.5

20

30

40

50

60

70

80

90

0 LFM

0

0.5

1

1.5

2

2.5

3

3.5

20

30

40

50

60

70

80

90

0 LFM

AMBIENT TEMPERATURE, T

A

O

C

Figure 21. Derating Output Current versus Local
Ambient Temperature and Airflow

(

V

IN

= 5.0Vdc,

Vo=0.75 Vdc).

Figure 24. Derating Output Current versus Local
Ambient Temperature and Airflow (V

IN

= 3.3dc,

Vo=0.75 Vdc).

Advertising