Page 14

continuously. At the point of current-limit inception, the unit
enters hiccup mode. The unit operates normally once the output
current is brought back into its specified range.

Overtemperature Protection

To provide protection in a fault condition, the unit is equipped
with a thermal shutdown circuit. The unit will shutdown if the
overtemperature threshold of 140

o

C is exceeded at the thermal

reference point T

ref

. The thermal shutdown is not intended as a

guarantee that the unit will survive temperatures beyond its
rating. Once the unit goes into thermal shutdown it will then
wait to cool before attempting to restart.

Input Undervoltage Lockout

At input voltages below the input undervoltage lockout limit, the
module operation is disabled. The module will begin to operate
at an input voltage above the undervoltage lockout turn-on
threshold.

Output Voltage Programming

The output voltage of the 12V PicoTLynx

TM

2A modules can be

programmed to any voltage from 0.6dc to 5.5Vdc by connecting
a resistor between the Trim and GND pins of the module.

Certain restrictions apply on the output voltage set point
depending on the input voltage. These are shown in the Output

Voltage vs. Input Voltage Set Point Area plot in Fig. 55. The
Lower Limit curve shows that for output voltages of 2.4V and
higher, the input voltage needs to be larger than the minimum

of 3V.

0

2

4

6

8

10

12

14

16

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

5.5

6

Output Voltage (V)

Input

Volt

ag

e

(v

)

Figure 55. Output Voltage vs. Input Voltage Set Point Area

plot showing limits where the output voltage can be set for
different input voltages.

Without an external resistor between Trim and GND pins, the

output of the module will be 0.6Vdc. To calculate the value of
the trim resistor, Rtrim for a desired output voltage, use the

following equation:

(

)

Ω

=

k

Vo

Rtrim

6

.

0

0

.

6

Rtrim is the external resistor in kΩ

Vo is the desired output voltage.

Table 1 provides Rtrim values required for some common output
voltages.

Table 1

V

O, set

(V)

Rtrim (KΩ)

1.0 15
1.2 10
1.5 6.67
1.8 5
2.5 3.16
3.3 2.22
5.0 1.36


By using a ±0.5% tolerance trim resistor with a TC of
±100ppm, a set point tolerance of ±1.5% can be
achieved as specified in the electrical specification.

Remote Sense

The 12V PicoTLynx

TM

2A power modules have a Remote

Sense feature to minimize the effects of distribution
losses by regulating the voltage at the SENSE pin. The
voltage between the SENSE pin and VOUT pin must not
exceed 0.5V. Note that the output voltage of the module
cannot exceed the specified maximum value. This
includes the voltage drop between the SENSE and Vout

pins. When the Remote Sense feature is not being used,

connect the SENSE pin to the VOUT pin.

V

O

(+)

TRIM

GND

R

trim

LOAD

V

IN

(+)

ON/OFF

SENSE

Figure 56. Circuit configuration for programming
output voltage using an external resistor.

Voltage Margining

Output voltage margining can be implemented in the

12V PicoTLynx

TM

2A modules by connecting a resistor,

R

margin-up

, from the Trim pin to the ground pin for

margining-up the output voltage and by connecting a

resistor, R

margin-down

, from the Trim pin to output pin for

margining-down. Figure 10 shows the circuit
configuration for output voltage margining. The POL

Programming Tool, available at

www.lineagepower.com

under the Design Tools section, also calculates the values

of R

margin-up

and R

margin-down

for a specific output voltage

and % margin. Please consult your local GE Critical
Power technical representative for additional details.

Advertising