Instructions

SK (Max Amps)

Catalog Numbers

Trip Amps

800

1000

1200

GTP0300U0408

300

x

GTP0350U0408

350

x

GTP0400U0410

400

x

GTP0450U0612

450

x

x

x

GTP0500U0613

500

x

x

x

GTP0600U0616

600

x

x

x

GTP0700U0816

700

x

x

x

GTP0750U0820

750

x

x

x

GTP0800U0820

800

x

x

x

GTP0900U1020

900

x

x

GTP1000U1025

1000

x

x

GTP1100U1225

1100

x

GTP1200U1232

1200

x

Table 1. Catalog numbering system for Spectra® RMS SK Frame breakers with microEntelliGuard™ trip units


SK PC 36 12 L4 R 6

Code Description

Function

SK

SK1200

Frame Designation

HC
LC/TC

1

PC/SC

1

HH
LL/TT

1

PP/SS

1

50kA at 480Vac

65kA at 480Vac

Standard UL Rating

100kA at 480 Vac

50kA at 480Vac

65kA at 480Vac

100% Continuous UL Rating

100kA at 480 Vac

Interruption Rating

3, 4 or 6 3 Poles, 480Vac or 600Vac

Poles, Max UL Voltage

08

800 Amps

10

1000 Amps

SK Frame

12

1200 Amps

L3

LSI

L = Long Time

S = Short Time

L4

LSIG

I = Instantaneous

L5

LSIA

G = Ground Fault

A = Ground Fault Alarm

L7

LSI-CP

CP = Control Power

X

None

K

Neutral Protection

Z

ZSI (ST/GF)

T

ZSI (ST/GF/INST)

R

RELT

L

ZSI (ST/GF) + RELT

M

ZSI (ST/GF) + Neutral Protection

N

ZSI (ST/GF) + RELT + Neutral Protection

V

RELT + Neutral Protection

P

ZSI (ST/GF/INST) + RELT

S

ZSI (ST/GF/INST) + Neutral Protection

W

ZSI (ST/GF/INST) + RELT + Neutral Protection

X

Metering (Basic)

2

Metering (Basic) + Modbus

6

Metering (Adv) + Modbus + Waveform Capture

8

Metering (Adv) + Modbus + Waveform Capture + Protective Relays

Max Amps


Standard Protection
Functions





Advanced Protection
Functions





Advanced Features &
Communications



Example – a breaker with catalog number

SKPC3612L4R6 has the following features:

1 SK1200 frame (SK)

2 100 kA at 480 Vac Standard UL rating (PC)

3 3 pole, 600 Vac maximum (36)

4 1200 A sensors (12)

5 Long-time, Short-time, Instantaneous and Ground

Fault functions (L4)

6 RELT – Reduced Energy Let-Through (R)

7 Advance Metering, Modbus Communications, and

Waveform Capture (6)

2. Following the instructions supplied with the rating

plug, install the plug into the breaker body. Available
rating plugs, with their catalog numbers, are listed in
Table 2.

1. SKT and SKS catalog codes are optimized for selectivity and will carry a
480Vac maximum voltage rating.

Table 2. SK Frame Rating Plugs