Data Sheet

October 5, 2013

EQW010-040 Series Power Modules

36 – 75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current

LINEAGE

POWER

4

Electrical Specifications

(continued)

Parameter

Device

Symbol

Min

Typ

Max

Unit

Dynamic Load Response

(dIo/dt=0.1A/

s; V

IN

= V

IN, nom

; T

A

=25°C)

Load Change from Io= 50% to 75% or 25% to
50% of Io,max;

Peak Deviation

All

V

pk

3

% V

O, set

Settling Time (Vo<10% peak deviation)

All t

s

200

s

(dIo/dt=1A/

s; V

IN

= V

IN, nom

; T

A

=25°C)

Load Change from Io= 50% to 75% or 25% to
50% of Io,max;

Peak Deviation

All

V

pk

5

% V

O, set

Settling Time (Vo<10% peak deviation)

All t

s

200

s

Isolation Specifications

Parameter

Device

Symbol

Min

Typ

Max

Unit

Isolation Capacitance

All

C

iso

1000

pF

Isolation Resistance

All

R

iso

10

MΩ

I/O Isolation Voltage (100% factory Hi-pot tested)

All

All

1500 V

dc

General Specifications

Parameter

Device

Symbol

Min

Typ

Max

Unit

Calculated Reliability based upon Telcordia SR-
332 Issue 2: Method

I

Case 3 (I

O

=80%I

O, max

,

T

A

=40°C, airflow = 200 lfm, 90% confidence)

B FIT

334

10

9

/Hours

A-S FIT

290

10

9

/Hours

F FIT

328

10

9

/Hours

Y FIT

302

10

9

/Hours

B MTBF

2,997,896

Hours

A-S MTBF

3,451,558

Hours

F MTBF

3,051,626

Hours

Y MTBF

3,312,888

Hours

Weight All

20.5

(0.72)

g

(oz.)

Advertising