Data Sheet

October 5, 2013

EQW010-040 Series Power Modules

36 – 75Vdc Input; 1.0 to 12.0Vdc Output; 10 to 40A Output Current

LINEAGE

POWER

5

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low - Remote On/Off Current

All

I

on/off

1.0 mA

Logic Low - On/Off Voltage

All

V

on/off

-0.7

1.2 V

dc

Logic High Voltage – (Typ = Open Collector)

All

V

on/off

5

V

dc

Logic High maximum allowable leakage current

All

I

on/off

10

μA

Turn-On Delay and Rise Times

(I

O

=I

O, max ,

V

IN

=V

IN, nom,

T

A

= 25

o

C)

Case 1: On/Off input is set to Logic Low (Module
ON) and then input power is applied (T

delay

from

instant at which V

IN

= V

IN, min

until Vo=10% of V

O,set

)

All
B*

T

delay

T

delay


20
25

25
30

msec
msec

Case 2: Input power is applied for at least 1 second
and then the On/Off input is set from OFF to ON (T

delay

=

from instant at which V

IN

=V

IN, min

until V

O

= 10% of V

O, set

).

All
B*

T

delay

T

delay


5

25

10
30

msec
msec

Output voltage Rise time (time for Vo to rise from 10%
of V

o,set

to 90% of V

o, set

)

All T

rise

― 8 12

msec

Output voltage Rise time (time for Vo to rise from 10%
of V

o,set

to 90% of V

o, set

with max ext capacitance)

All T

rise

― 8 12

msec

Output voltage overshoot – Startup

All

― 3

%

V

O, set

I

O

= I

O, max

; V

IN

=V

IN, min

to V

IN, max

, T

A

= 25

o

C

Remote Sense Range

G, Y, M,

P, S1R0

V

SENSE

0.25 Vdc

(Max voltage drop is 0.5V)

B*, A, F

V

SENSE

10 %

V

O, set

Output Voltage Adjustment Range

All*

80

110

% V

O, set

Output Overvoltage Protection

B V

O, limit

14

16 V

dc

A

V

O, limit

5.7

6.5 V

dc

F

V

O, limit

3.8

4.6 V

dc

G

V

O, limit

2.9

3.4 V

dc

Y

V

O, limit

2.3

2.6 V

dc

M

V

O, limit

1.8

2.2 V

dc

P

V

O, limit

1.4

1.6 V

dc

S1R0

V

O, limit

1.2

1.4 V

dc

Input Undervoltage Lockout

All

V

UVLO

Turn-on Threshold

30 34.5 36 V

dc

Turn-off Threshold

30 32

V

dc

Hysterisis

1.5

2

V

dc

Input Overvoltage Lockout

All

V

OVLO

Turn-on Threshold

80

V

dc

Turn-off Threshold

75 79 83 V

dc

Hysterisis

2

3.5

V

dc

* Note: 12.0V

O

(B) device codes have an adaptable extended Turn-On Delay interval, T

delay

, as specified for B* devices. The extended T

delay

will occur

when a 12V

O

module restarts following either 1) the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout and then back

to normal; or 2) toggling the on/off signal from on to off and back to on without removing the input voltage. The normal Turn-On Delay interval, T

delay

,

as specified for All Devices, will occur whenever a 12V

O

module restarts with input voltage removed from the module for the preceding 1 second.

12.0V

O

(B) also achieves +10% V

O, set

Remote Sense drop or trim up to 110% V

O, set

only above Vin = 40V

dc

.

Advertising