QBDW025A0B Barracuda Series; DC-DC Converter Power Modules

36-75Vdc Input; 12.0Vdc, 25.0A, 300W Output

May 9, 2013

©2012 General Electric Company. All rights reserved.

Page 19

The module can provide temperature information using the

READ_TEMPERATURE_1 command. The command returns
two bytes of data in the linear format. The upper five bits [7:3]
of the high data byte form the two’s complement

representation of the exponent, which is fixed at –2 (decimal).
The remaining 11 bits are used for two’s complement

representation of the mantissa.

Note that the module’s temperature sensor is located

close

to the module hot spot TH

1

(see Thermal Considerations).and

is subjected to

temperatures higher than the ambient air

temperature near the module. The temperature reading will
be highly influenced by module load and airflow conditions.

Reading the Status of the Module using the PMBus

The module supports a number of status information
commands implemented in PMBus. However, not all

features

are supported in these commands. A X in the FLAG cell

indicates the bit is not supported.

STATUS_WORD : Returns two bytes of information with a
summary of the module’s fault/warning conditions.

High Byte

Bit Position

Flag

Default Value

15 VOUT

fault 0

14

IOUT fault or warning

0

13

Input Voltage fault

0

12 X 0
11 POWER_GOOD#

(is

negated) 0

10 X 0

9 X 0
8 X 0

Low Byte

Bit Position

Flag

Default Value

7 X 0
6 OFF 0
5 VOUT

Overvoltage 0

4 IOUT

Overcurrent 0

3 VIN

Undervoltage 0

2 Temperature 0
1

CML (Comm. Memory Fault)

0

0 X 0


STATUS_VOUT : Returns one byte of information relating to
the status of the module’s output voltage related faults.

Bit Position

Flag

Default Value

7

VOUT OV Fault

0

6 X 0
5 X 0
4 X 0
3 X 0
2 X 0
1 X 0
0 X 0

STATUS_IOUT : Returns one byte of information relating to the

status of the module’s output currentrelated faults.

Bit Position

Flag

Default Value

7

IOUT OC Fault

0

6 X 0
5

IOUT OC Warning

0

4 X 0
3 X 0
2 X 0
1 X 0
0 X 0

STATUS_INPUT : Returns one byte of information relating to
the status of the module’s input voltage related faults.

Bit Position

Flag

Default Value

7 VIN

OV

Fault 0

6 X 0
5 X 0
4

VIN UV Fault

0

3

Module Off (Low VIN)

0

2 X 0
1 X 0
0 X 0

STATUS_TEMPERATURE : Returns one byte of information
relating to the status of the module’s temperature related
faults.

Bit Position

Flag

Default Value

7 OT

Fault 0

6 OT

Warning 0

5 X 0
4 X 0
3 X 0
2 X 0
1 X 0
0 X 0

STATUS_CML : Returns one byte of information relating to the

status of the module’s communication related faults.

Bit Position

Flag

Default Value

7

Invalid/Unsupported

Command

0

6 Invalid/Unsupported

Data 0

5

Packet Error Check Failed

0

4 X 0
3 X 0
2 X 0
1 X 0
0 X 0