Feature Description (continued)

control loop of the module, typically causing the loop to slow
down with sluggish response. Larger values of external

capacitance could also cause the module to become
unstable.

The Tunable Loop

TM

allows the user to externally adjust the

voltage control loop to match the filter network connected to
the output of the module. The Tunable Loop

TM

is implemented

by connecting a series R-C between the SENSE(+) and TRIM
pins of the module, as shown in Fig. 17. This R-C allows the
user to externally adjust the voltage loop feedback

compensation of the module.

Figure 17. Circuit diagram showing connection of R

TUNE

and

C

TUNE

to tune the control loop of the module.

Table 1 shows the recommended values of R

TUNE

and C

TUNE

for

different values of ceramic output capacitors up to 8000 F

that might be needed for an
application to meet output ripple and noise requirements.

Table 1. General recommended values of of R

TUNE

and C

TUNE

for V

out

=32V and various external ceramic capacitor

combinations.

C

out

(µF)

1100

2200

4400

6600

8800

ESR (mΩ)

60

30

15

10

7.5

R

TUNE

* * * * *

C

TUNE

* * * * *

* contact GE technical support
Please contact your GE technical representative to obtain
more details of this feature as well as for guidelines on how to
select the right value of external R-C to tune the module for
best transient performance and stable operation for other
output capacitance values.

Over Temperature Protection

The JRCK017S32R0 module provides a non-latching over
temperature protection. A temperature sensor monitors the

operating temperature of the converter. If the reference
temperature, T

REF 1

, (see Figure 17) exceeds a threshold of 115

ºC (typical), the converter will shut down and disable the

output. When the base plate temperature has decreased by
approximately 20 ºC the converter will automatically restart.
The module can be restarted by cycling the dc input power for
at least one second or by toggling the remote on/off signal for
at least one second.

Thermal Considerations

The power modules operate in a variety of thermal
environments; however, sufficient cooling should be provided

to help ensure reliable operation.

Considerations include ambient temperature, airflow, module
power dissipation and the need for increased reliability. A

reduction in the operating temperature of the module will
result in an increase in reliability.

The thermal data presented here is based on physical
measurements taken in a wind tunnel, using automated
thermo-couple instrumentation to monitor key component

temperatures: FETs, diodes, control ICs, magnetic cores,
ceramic capacitors, opto-isolators, and module pwb
conductors, while controlling the ambient airflow rate and

temperature. For a given airflow and ambient temperature,
the module output power is increased, until one (or more) of

the components reaches its maximum derated operating
temperature, as defined in IPC-9592. This procedure is then
repeated for a different airflow or ambient temperature until a

family of module output derating curves is obtained.

Heat-dissipating components inside the unit are thermally

coupled to the case. Heat is removed by conduction,
convection, and radiation to the surrounding environment.
Proper cooling can be verified by measuring the case

temperature. Peak temperature locations (Tref) occur at the
positions indicated in Figure 18.

For reliable operation, these temperatures should not

exceed the values listed below for applications using forced
convection airflow or coldwall applications.

Application

Tref1

Tref2

Coldwall 99

100

Heatplate only, or w/Heatsink

95

100


The output power of the module should not exceed the rated
power for the module as listed in the ordering Information
table. Although the maximum T

REF

temperature of the power

modules is discussed above, you can limit this temperature to
a lower value for extremely high reliability.

Advertising