Data sheet, Isolation specifications, General specifications – GE Industrial Solutions JRCK017A0S32R0 Orca Series User Manual

Page 4: Feature specifications

Advertising
background image

GE

Data Sheet

JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules

36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output

October 11, 2013

©2012 General Electric Company. All rights reserved.

Page 4

Isolation Specifications

Parameter

Symbol

Min

Typ

Max

Unit

Isolation Capacitance

C

iso

15

nF

Isolation Resistance

R

iso

10

MΩ

General Specifications

Parameter

Device

Symbol

Min

Typ

Max

Unit

Calculated Reliability based upon Telcordia SR-332 Issue 2:
Method

I

Case 3 (I

O

=80%I

O, max

, T

A

=40°C, airflow = 200 lfm, 90%

confidence)

All

FIT 476.1

10

9

/Hours

MTBF 2,100,581 Hours

Weight All

76.4 (

2.69)

g (

oz.)

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low - Remote On/Off Current

All

I

on/off

1.0 mA

Logic Low - On/Off Voltage

All

V

on/off

0

1.2 V

dc

Logic High Voltage – (Typ = Open Collector)

All

V

on/off

5 V

dc

Logic High maximum allowable leakage current

All

I

on/off

50

μA

Turn-On Delay and Rise Times

(Vin=V

in,nom

, I

O

=I

O, max

, 25C)

Case 1: T

delay

= Time until V

O

= 10% of V

O,set

from application

of V

in

with Remote On/Off set to ON,

All

T

delay

120 ms

Case 2: T

delay

= Time until V

O

= 10% of V

O,set

from application of

Remote On/Off from Off to On with V

in

already applied for at

least one second.

All T

delay

20 ms

T

rise

= time for V

O

to rise from 10% of V

O,set

to 90% of V

O,set

. All T

rise

45 55 65 ms

Output Voltage Overshoot

3 %

V

O, set

(I

O

=80% of I

O, max

, T

A

=25°C)

Output Voltage Adjustment
(See Feature Descriptions):





Output Voltage Remote-sense Range
(only for No Trim or Trim down application )

All V

sense

__

__

2 %V

o,nom

Output Voltage Set-point Adjustment Range (trim)

All

V

trim

16.0 --- 35.2 V

dc

Output Overvoltage Protection

All

V

O, limit

37

39 V

dc

Over Temperature Protection

All

T

ref

110

°C

(See Feature Descriptions, Figure 17)

Input Under Voltage Lockout

V

IN, UVLO

Turn-on Threshold

All

35 36 V

dc

Turn-off Threshold

All

30.5 32.5

V

dc

Hysteresis All

3 V

dc

Input Over voltage Lockout

V

IN, OVLO

Turn-on Threshold

All

62

66

V

dc

Turn-off Threshold

All

66

68

V

dc

Hysteresis All

--- 3 --- V

dc

Advertising