Naos Raptor 60A: Non Isolated Power Modules

5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current


LINEAGE

POWER

13

Power Good

The Naos Raptor 60A power modules provide a
Power Good Status signal that indicates whether or
not the power module is functioning properly.
PwGood is a power good signal implemented with an
open-collector output to indicate that the output
voltage is within the regulation limits of the power
module. The PwGood signal will be de-asserted to a
low state If any condition such as over-temperature,
over-current, or over-voltage occurs which would
result in the output voltage going out of range.

Output Voltage Programming

The output voltage of the Naos Raptor 60A module
can be programmed to any voltage from 0.6Vdc to
5.0Vdc by connecting a resistor between the Trim +
and Trim - pins of the module. Without an external
resistor between Trim + and Trim - pins, the output of
the module will be 0.6Vdc. To calculate the value of
the trim resistor, Rtrim for a desired output voltage,
use the following equation:

Ω

=

k

Vo

Rtrim

)

6

.

0

(

2

.

1

Rtrim is the external resistor in kΩ
Vo is the desired output voltage

Table 2 provides Rtrim values required for some
common output voltages.

By using a ±0.1% tolerance trim resistor with a TC of
±25ppm, a set point tolerance of ±0.8% can be
achieved as specified in the electrical specification.
The POL Programming Tool available at

www.lineagepower.com

under the Design Tools

section, helps determine the required trim resistor
needed for a specific output voltage.

Note: Vin ≥ 180% of Vout at the module output pin.

V

O

(+)

TRIM+

GND

R

trim

LOAD

V

IN

(+)

ON/OFF

Vout

TRIM

Figure 42. Circuit configuration for programming
output voltage using an external resistor.

Table 2

V

O, set

(V)

Rtrim (Ω)

0.6 Open
1.0 3000
1.2 2000
1.5 1333
1.8 1000
2.5 632
3.3 444
5.0 273

Monotonic Start-up and Shutdown

The Naos Raptor 60A modules have monotonic start-
up and shutdown behavior for any combination of
rated input voltage, output current and operating
temperature range.