December 6, 2010

Naos Raptor 60A: Non Isolated Power Modules

5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

Continuous All

V

IN

-0.3 15 Vdc

Operating Ambient Temperature

All

T

A

0 70 °C

(see

Thermal

Considerations

section)

Storage Temperature

All

T

stg

-55 125 °C

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

5

12.0

13.8

Vdc

Maximum Input Current

All

I

IN,max

40

Adc

(V

IN

= V

IN, min

to V

IN, max

, I

O

=I

O, max

V

O,set

= 3.3Vdc)

Input No Load Current

(V

IN

= 9Vdc, I

O

= 0, module ON)

V

O,set

= 0.6 Vdc

I

IN,No load

36

mA

(V

IN

= 12Vdc, I

O

= 0, module ON)

V

O,set

= 5.0Vdc

I

IN,No load

86

mA

Input Stand-by Current

All

I

IN,stand-by

1

mA

(V

IN

= 12Vdc, module disabled)

Inrush Transient

All

I

2

t

1

A

2

s

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V

IN, min

to

V

IN, max,

I

O

= I

Omax

; See Test configuration section)

All

150

mAp-p

Input Ripple Rejection (120Hz)

All

50

dB

Advertising