Data Sheet
December 6, 2010
Naos Raptor 60A: Non Isolated Power Modules
5 – 13.8Vdc input; 0.6Vdc to 5.0Vdc Output; 60A output current
LINEAGE
POWER
2
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
Continuous All
V
IN
-0.3 15 Vdc
Operating Ambient Temperature
All
T
A
0 70 °C
(see
Thermal
Considerations
section)
Storage Temperature
All
T
stg
-55 125 °C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
All
V
IN
5
12.0
13.8
Vdc
Maximum Input Current
All
I
IN,max
40
Adc
(V
IN
= V
IN, min
to V
IN, max
, I
O
=I
O, max
V
O,set
= 3.3Vdc)
Input No Load Current
(V
IN
= 9Vdc, I
O
= 0, module ON)
V
O,set
= 0.6 Vdc
I
IN,No load
36
mA
(V
IN
= 12Vdc, I
O
= 0, module ON)
V
O,set
= 5.0Vdc
I
IN,No load
86
mA
Input Stand-by Current
All
I
IN,stand-by
1
mA
(V
IN
= 12Vdc, module disabled)
Inrush Transient
All
I
2
t
1
A
2
s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN, min
to
V
IN, max,
I
O
= I
Omax
; See Test configuration section)
All
150
mAp-p
Input Ripple Rejection (120Hz)
All
50