11

—————— I/O Expansion card ——————

D14A4F

4. JUMPERS

Name

Default

S2 Adaptation to the input signal of analog input 0

OFF

ON 0 … 20mA / 4 … 20mA

OFF 0 … 10V / -10V … +10V

S3 Adaptation to the input signal of analog input 1

OFF

ON 0 … 20mA / 4 … 20mA

OFF 0 … 10V / -10V … +10V

S7

ON 0 Channel included in the encoder loss logic

OFF

OFF 0 Channel not included in the encoder loss logic

expD70

Description

EXP-D14A4F board

Set Jumper to ON when encoder loss detection is used also for zero channel.
(Alarm active only if a digital encoder with all A, Anot, B, Bnot channels and
+15V/24V power supply is used).

I/O available depending on drive firmware version

Drive firmware

1.X

from 2.X

Digital Inputs

4

8

Digital Outputs

6

6

Analog Inputs

-

2

Analog Outputs

2

2

Encoder Input

1

1