Data Sheet
July 11, 2011

Naos Raptor 20A: Non Isolated Power Module:

4.5 – 14Vdc input; 0.59Vdc to 6Vdc Output; 20A output current

LINEAGE

POWER

18

Recommended Pad Layout


Dimensions are in millimeters and (inches).
Tolerances: x.x mm

± 0.2 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated]

x.xx mm

± 0.12 mm (x.xxx in ± 0.005 in.)

Pin Function Pin Function

1 V

out

6 V

in

2

Trim +

7

Sense +

3 GND 8 Sense

-

4 PwGood 9 TRIM

-

5 On/Off 10 GND