Data Sheet
JRCW450R Orca Series; DC-DC Converter Power Modules
36–75 Vdc Input; 32.0Vdc Output; 450W Output
May 8, 2013
©2012 General Electric Company. All rights reserved.
Page 3
Electrical Specifications
(continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
Output Voltage Set-point
(V
IN
=V
IN,nom
, I
O
=I
O, max
, T
c
=25°C)
All
V
O, set
31.5 32 32.5 V
dc
Output Voltage Set-Point Total Tolerance
(Over all operating input voltage, resistive load, and temperature
conditions until end of life)
All V
O
31.0
33.0
V
dc
Output
Regulation
Line (V
IN
=V
IN, min
to V
IN, max
) All
0.1 0.2
%V
o,set
Load (I
O
=I
O, min
to I
O, max
) All
0.1 0.2
%V
o,set
Temperature (T
c
= -40ºC to +100ºC)
All
0.25 0.5 %V
o,set
Output Ripple and Noise on nominal output
(V
IN
=V
IN, nom
and I
O
=I
O, min
to I
O, max
)
RMS (5Hz to 20MHz bandwidth)
All
45 55
mV
rms
Peak-to-Peak (5Hz to 20MHz bandwidth)
All
80
200
mV
pk-pk
External Capacitance
(ESR
> TBD mΩ)
1
All,
except -T
C
O
440 6500
μF
Without the Tunable Loop
(ESR
MAX
= 80mΩ)
1
-T
C
O,
440 470 μF
With the Tunable Loop
(ESR > 50 mΩ)
2
-T C
O
440
10,000
μF
Output Power (V
o
=32V to 35.2V)
All
P
O,max
450 W
Output Current
All
I
o
0
14.0
A
dc
Output Current Limit Inception (Constant current until V
o
<
V
trimMIN
,
duration <4s)
All
I
O, lim
16.0
20.0 A
dc
Output Short Circuit Current (V
O
≤ 0.25V
dc
)
All
I
O, sc
60
A
pk
Hiccup mode
5
A
rms
Efficiency
V
IN
=V
IN, nom
, T
c
=25°C I
O
=I
O, max ,
V
O
= V
O,set
All
η 94.0
94.4
%
Switching Frequency
f
sw
175
kHz
Dynamic
Load
Response
(Io/t=1A/10s; V
in
=V
in
,nom; T
c
=25°C; Tested with a 470 μF
aluminum and a 10 µF ceramic capacitor across the load.)
Load Change from Io= 50% to 75% of Io,max:
Peak Deviation
Settling Time (Vo<10% peak deviation)
All
V
pk
t
s
2
1.5
%V
O, set
ms
Load Change from Io= 25% to 50% of Io,max:
Peak Deviation
Settling Time (Vo<10% peak deviation)
V
pk
t
s
2
1.5
%V
O, set
ms
1
Note: use a minimum 2 x 220uF output capacitor. Recommended capacitor is Nichicon CD series, 220uF/35V. If the ambient temperature is less
than -20
O
C, use more than 3 of recommended minimum capacitors.
2
External capacitors may require using the new Tunable Loop feature to ensure that the module is stable as well as getting the best transient
response. See the Tunable Loop section for details.
Isolation Specifications
Parameter
Symbol
Min
Typ
Max
Unit
Isolation Capacitance
C
iso
15
nF
Isolation Resistance
R
iso
10
MΩ